Randomized, controlled, phase 3 study to evaluate the safety and efficacy of fibrin sealant VH S/D 4 s-apr (Artiss) to improve tissue adherence in subjects undergoing rhytidectomy
- PMID: 23563904
- DOI: 10.1177/1090820X13479969
Randomized, controlled, phase 3 study to evaluate the safety and efficacy of fibrin sealant VH S/D 4 s-apr (Artiss) to improve tissue adherence in subjects undergoing rhytidectomy
Abstract
Background: Suction drains are commonly placed after rhytidectomy to avoid seroma formation that may result from dead spaces between skin layers. Fibrin sealants promote tissue adherence by crosslinking with extracellular matrix proteins, which may reduce the dead space under skin flaps.
Objectives: The authors evaluate the safety and efficacy of the fibrin sealant (FS) VH S/D 4 s-apr (Artiss; Baxter Healthcare Corp, Deerfield, Illinois), added to standard-of-care (SoC) treatment, in improving flap adherence and reducing dead space in patients undergoing rhytidectomy.
Methods: Patients with planned facial rhytidectomy were enrolled in this phase 3, prospective, controlled, randomized, patient-blinded, multicenter trial. They received SoC treatment on 1 side of the face and adjunctive FS VH S/D 4 s-apr on the other.
Results: Seventy-five patients completed the trial. The mean (SD) drainage volume was 7.7 (7.4) mL from the sides treated with sealant and 20.0 (11.3) mL from the SoC-only sides (P < .0001). Rates of hematoma and seroma were similar for the 2 treatments, as were changes in postoperative skin sensitivity. Adverse events generally were mild; 2 serious adverse events were reported (wound abscess, dehydration).
Conclusions: Adjunct use of FS VH S/D 4 s-apr in rhytidectomy was proven safe in this study. It significantly reduced drainage volumes without increasing the incidence of hematoma or seroma, which suggests that it eliminates dead space through improved flap adherence.
Level of evidence: 2.
Trial registration: ClinicalTrials.gov NCT00999141.
Keywords: facial surgery; fibrin sealant; rhytidectomy; tissue adherence.
Similar articles
-
Exploratory, randomized, controlled, phase 2 study to evaluate the safety and efficacy of adjuvant fibrin sealant VH S/D 4 S-Apr (ARTISS) in patients undergoing rhytidectomy.Aesthet Surg J. 2013 Mar;33(3):323-33. doi: 10.1177/1090820X13477860. Aesthet Surg J. 2013. PMID: 23515377 Clinical Trial.
-
A comparison of the efficacy of autologous fibrin glue/platelet-poor plasma versus suction drainage in preventing hematoma and seroma in rhytidectomy: A randomized, double-blind, controlled study.J Plast Reconstr Aesthet Surg. 2021 Sep;74(9):2290-2295. doi: 10.1016/j.bjps.2020.12.098. Epub 2021 Jan 10. J Plast Reconstr Aesthet Surg. 2021. PMID: 33583759 Clinical Trial.
-
Efficacy and safety of a fibrin sealant for adherence of autologous skin grafts to burn wounds: results of a phase 3 clinical study.J Burn Care Res. 2008 Mar-Apr;29(2):293-303. doi: 10.1097/BCR.0b013e31816673f8. J Burn Care Res. 2008. PMID: 18354285 Clinical Trial.
-
Tissue sealants may reduce haematoma and complications in face-lifts: A meta-analysis of comparative studies.J Plast Reconstr Aesthet Surg. 2017 Mar;70(3):297-306. doi: 10.1016/j.bjps.2016.11.028. Epub 2016 Dec 15. J Plast Reconstr Aesthet Surg. 2017. PMID: 28043785 Review.
-
A Systematic Review: Fibrin Glue in Drainless Rhytidoplasty.Aesthetic Plast Surg. 2024 Jun;48(12):2224-2230. doi: 10.1007/s00266-024-03908-3. Epub 2024 Mar 8. Aesthetic Plast Surg. 2024. PMID: 38456891
Cited by
-
Methods for Minimizing Bleeding in Facelift Surgery: An Evidence-based Review.Plast Reconstr Surg Glob Open. 2021 Aug 12;9(8):e3765. doi: 10.1097/GOX.0000000000003765. eCollection 2021 Aug. Plast Reconstr Surg Glob Open. 2021. PMID: 34395151 Free PMC article.
-
How to Prevent and Treat Complications in Facelift Surgery, Part 1: Short-Term Complications.Aesthet Surg J Open Forum. 2021 Feb 10;3(1):ojab007. doi: 10.1093/asjof/ojab007. eCollection 2021 Jan. Aesthet Surg J Open Forum. 2021. PMID: 34212140 Free PMC article.
-
Prevention of subcutaneous seroma formation in open ventral hernia repair using a new low-thrombin fibrin sealant.World J Surg. 2014 Nov;38(11):2797-803. doi: 10.1007/s00268-014-2691-z. World J Surg. 2014. PMID: 24981370
-
Fibrin Sealants in Facial Plastic Surgery: A National Database Analysis of Complication Risk.OTO Open. 2025 Mar 26;9(1):e70102. doi: 10.1002/oto2.70102. eCollection 2025 Jan-Mar. OTO Open. 2025. PMID: 40143956 Free PMC article.
-
Clinical applications of surgical adhesives and sealants.Crit Rev Biomed Eng. 2014;42(3-4):271-92. doi: 10.1615/critrevbiomedeng.2014011676. Crit Rev Biomed Eng. 2014. PMID: 25597240 Free PMC article. Review.
Publication types
MeSH terms
Substances
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous