Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Jul-Aug;32(4):227-33.
doi: 10.1016/j.remn.2013.02.004. Epub 2013 Apr 6.

Added value of the hybrid tracer indocyanine green-99mTc-nanocolloid for sentinel node biopsy in a series of patients with different lymphatic drainage patterns

Affiliations

Added value of the hybrid tracer indocyanine green-99mTc-nanocolloid for sentinel node biopsy in a series of patients with different lymphatic drainage patterns

L M Frontado et al. Rev Esp Med Nucl Imagen Mol. 2013 Jul-Aug.

Abstract

Introduction: Indocyanine green (ICG)-(99m)Tc-nanocolloid is a novel hybrid fluorescent radioactive tracer for sentinel node (SN) biopsy. This study has aimed to evaluate the added value of this novel versatile tracer in a series of patients with different malignancies.

Material and methods: Twenty patients (with penile carcinoma, oral cavity tumors, melanoma) were consecutively included between March-May 2012. Planar lymphoscintigraphy was performed 15 min and 2h after injection of ICG-(99m)Tc-nanocolloid followed by SPECT/CT. Blue dye (1 ml) was injected in 14 patients in surgery room. Intraoperatively, SNs were localized using a gamma probe and visualized by optical SN-detection using blue dye and fluorescence imaging. Finally, a portable gamma camera was used to confirm complete SN removal.

Results: At least one SN was identified by SPECT/CT in all patients. All SNs (total 68, 100%) were excised using a combination of radio- and fluorescence guidance: 89.7% were intraoperatively localized with the gamma probe. The remaining SNs, located near the injection site, were localized using fluorescence imaging. During the surgery, 97% of the SNs were fluorescent while only 39.2% were stained blue. Ex vivo, all SNs were both radioactive and fluorescent. The SN was positive in 5 patients.

Conclusion: Synchronous radio- and fluorescence guided SN biopsy is feasible using ICG-(99m)Tc-nanocolloid. This hybrid approach combines the beneficial properties of both modalities. Adding fluorescence imaging improves optical SN detection compared to blue dye. It has been shown to be especially useful in the localization of SNs near the injection site.

PubMed Disclaimer

Substances

LinkOut - more resources