Conjunctival erosion after glaucoma drainage device surgery: a feasible option

Affiliations
Case Reports

Conjunctival erosion after glaucoma drainage device surgery: a feasible option

Suneeta Dubey et al. Indian J Ophthalmol. 2013 Jul.

Abstract

Glaucoma drainage devices (GDDs) have been used in the management of complicated glaucomas. GDDs are associated with various complications such as tube migration, tube or plate exposure or extrusion, ocular motility disturbance and infection. Erosion of conjunctiva and exposure of the GDD remains a risk factor for the development of endophthalmitis. A wide range of materials have been used for this purpose, including sclera, dura, pericardium, fascia lata and cornea. However, there is no evidence to prove that any of these methods is superior to another for providing tectonic durability in the long term. In this report, we present a case of neovascular glaucoma, who developed conjunctival melting over the tube of an Ahmed Glaucoma Valve implant and was successfully managed with Cap Doxycycline.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest: None declared.

Figures

Figure 1
Figure 1
Avascularized and exposed scleral patch with functional implant
Figure 2
Figure 2
Showing total epithelialization over the exposed sclera
Figure 3
Figure 3
Last follow-up showing a completely covered tube with deep anterior chamber

References

    1. Molteno AC. New implant for drainage in glaucoma: Clinical trial. Br J Ophthalmol. 1969;53:606–15. - PMC - PubMed
    1. Assaad MH, Baerveldt G, Rockwood EJ. Glaucoma drainage devices: Pros and cons. Curr Opin Ophthalmol. 1999;34:349–52. - PubMed
    1. Nguyen QH. Avoiding and managing complications of glaucoma drainage implants. Curr Opin Ophthalmol. 2004;15:147–50. - PubMed
    1. Al-Torbak AA, Al Shahwan S, Al Jadaan I, Al-Hommadi A, Edward DP. Endophthalmitis associated with Ahmed Glaucoma Valve implant. Br J Ophthalmol. 2005;89:454–8. - PMC - PubMed
    1. Freedman J. Scleral patch grafts with molteno setons. Ophthalmic Surg. 1987;18:532–4. - PubMed

Publication types

MeSH terms