Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2013 Aug;42(2):132-9.
doi: 10.1002/uog.12479.

Sonographic measurement of lower uterine segment thickness to predict uterine rupture during a trial of labor in women with previous Cesarean section: a meta-analysis

Affiliations
Free article
Review

Sonographic measurement of lower uterine segment thickness to predict uterine rupture during a trial of labor in women with previous Cesarean section: a meta-analysis

N Kok et al. Ultrasound Obstet Gynecol. 2013 Aug.
Free article

Abstract

Objective: To evaluate the accuracy of antenatal sonographic measurement of lower uterine segment (LUS) thickness in the prediction of risk of uterine rupture during a trial of labor (TOL) in women with a previous Cesarean section (CS).

Methods: PubMed and EMBASE were searched to identify articles published on the subject of sonographic LUS measurement and occurrence of a uterine defect after delivery. Four independent researchers performed identification of papers and data extraction. Selected studies were scored on methodological quality, and sensitivity and specificity of measurement of LUS thickness in the prediction of a uterine defect were calculated. We performed bivariate meta-analysis to estimate summary receiver-operating characteristics (sROC) curves.

Results: We included 21 studies with a total of 2776 analyzed patients. The quality of included studies was good, although comparison was difficult because of heterogeneity. The estimated sROC curves showed that measurement of LUS thickness seems promising in the prediction of occurrence of uterine defects (dehiscence and rupture) in the uterine wall. The pooled sensitivity and specificity of myometrial LUS thickness for cut-offs between 0.6 and 2.0 mm was 0.76 (95% CI, 0.60-0.87) and 0.92 (95% CI, 0.82-0.97); cut-offs between 2.1 and 4.0 mm reached a sensitivity and specificity of 0.94 (95% CI, 0.81-0.98) and 0.64 (95% CI, 0.26-0.90). The pooled sensitivity and specificity of full LUS thickness for cut-offs between 2.0 and 3.0 mm was 0.61 (95% CI, 0.42-0.77) and 0.91 (95% CI, 0.80-0.96); cut-offs between 3.1 and 5.1 mm reached a sensitivity and specificity of 0.96 (95% CI, 0.89-0.98) and 0.63 (95% CI, 0.30-0.87).

Conclusions: This meta-analysis provides support for the use of antenatal LUS measurements in the prediction of a uterine defect during TOL. Clinical applicability should be assessed in prospective observational studies using a standardized method of measurement.

Keywords: Caesarean section; lower uterine segment; sonography; trial of labor; uterine rupture.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources