Pneumoperitoneum for neonatal laparoscopy: how safe is it?
- PMID: 23577821
- DOI: 10.1111/pan.12146
Pneumoperitoneum for neonatal laparoscopy: how safe is it?
Abstract
We present the case of a 3 day old term neonate who experienced a cardiopulmonary arrest during creation of pneumoperitoneum for laparoscopic repair of duodenal atresia. The arrest was thought likely to have occurred as a result of a gas embolism. We discuss the features of the neonatal circulation which may predispose neonates to embolic phenomena during laparoscopic procedures, and the potential benefit of priming the insufflation apparatus with carbon dioxide. The possibility of gas embolism should be considered when contemplating laparoscopic surgery in this patient group.
© 2013 Blackwell Publishing Ltd.