Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Sep 15:47:133-40.
doi: 10.1016/j.bios.2013.02.049. Epub 2013 Mar 21.

Polypyrrole-poly(3,4-ethylenedioxythiophene)-Ag (PPy-PEDOT-Ag) nanocomposite films for label-free electrochemical DNA sensing

Affiliations

Polypyrrole-poly(3,4-ethylenedioxythiophene)-Ag (PPy-PEDOT-Ag) nanocomposite films for label-free electrochemical DNA sensing

S Radhakrishnan et al. Biosens Bioelectron. .

Abstract

The electrochemical DNA hybridization sensing of bipolymer polypyrrole and poly(3,4-ethylenedioxythiophene) (PPy-PEDOT) nanotubes functionalized with Ag nanoparticles has been investigated. The bipolymer nanotubes are prepared by simple chemical route and silver nanoparticles (Ag) further deposited over the PPy-PEDOT nanotubes to form PPy-PEDOT-Ag nanocomposite films. DNA labeled at 5'end using 6-mercapto-1-hexhane (HS-ssDNA) is immobilized on the PPy-PEDOT-Ag surface to form PPy-PEDOT-Ag-S-ssDNA and hybridization sensing is done in phosphate buffer. The presence of Ag nanoparticles (~28±5nm) well dispersed in the polymer composite with high surface area, high electrical conductivity and catalytic activity provides desirable microenvironment for the immobilization of probe DNA with controlled orientation leading to increased hybridization efficiency with target DNA. The morphological and structural characterizations by a scanning electron microscope (SEM) and X-ray diffraction (XRD) confirm the nanotube structure of composite polymer while Raman measurements indicate the efficient interactions between the PPy, PEDOT, Ag and HS-ssDNA. The sensor effectively discriminates different target DNA sequences with PPy-PEDOT-Ag-S-ssDNA substrate. The observed dynamic detection range is found between 1×10(-11)M and 1×10(-14)M with the lowest detection limit (3 σ/b) of 5.4×10(-15)M. This observed value is of higher sensitivity than that for MWCNT-Ag, PANi-Au, MWCNT-PPy-Au and PPy-PANi-Au composites reported previously.

PubMed Disclaimer

Publication types

LinkOut - more resources