Comparison of a modified Fick method with thermodilution for determining cardiac output in critically ill patients on mechanical ventilation
- PMID: 2358558
- DOI: 10.1007/BF01705160
Comparison of a modified Fick method with thermodilution for determining cardiac output in critically ill patients on mechanical ventilation
Abstract
We compared a modified Fick method for measuring cardiac output against the thermodilution method in 11 critically-ill patients on mechanical ventilation. Oxygen consumption (VO2) was calculated indirectly, by measuring the carbon dioxide elimination (VCO2) during steady state and by assuming an average respiratory quotient of 0.9. For a total of 129 measurements, the mean difference in cardiac output between both methods was 0.03 +/- 1.3 l/min (95% confidence interval, -0.19 to 0.25 l/min, p = 0.7) standard deviation, with the largest differences being measured in the low cardiac output range (less than 5 l/min). No statistically significant difference was found between the cardiac output values obtained with either method. These data showed a good correlation between the two methods and suggest that the modified Fick method may be useful in determining cardiac output in seriously ill patients on mechanical ventilation not requiring pulmonary arterial catheterisation, or where facilities for undertaking metabolic measurements are not available.
Similar articles
-
Oxygen Fick and modified carbon dioxide Fick cardiac outputs.Crit Care Med. 1994 Jan;22(1):86-95. doi: 10.1097/00003246-199401000-00018. Crit Care Med. 1994. PMID: 8124981
-
Comparison between cardiac output measured by thermodilution technique and calculated by O2 and modified CO2 Fick methods using a new metabolic monitor.Intensive Care Med. 1997 Aug;23(8):908-15. doi: 10.1007/s001340050431. Intensive Care Med. 1997. PMID: 9310812
-
Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery.Crit Care Med. 1993 Sep;21(9):1369-75. doi: 10.1097/00003246-199309000-00022. Crit Care Med. 1993. PMID: 8370302
-
Continuous measurement of cardiac output by the Fick principle in infants and children: comparison with the thermodilution method.Intensive Care Med. 1996 May;22(5):467-71. doi: 10.1007/BF01712169. Intensive Care Med. 1996. PMID: 8796404 Review.
-
Issues in methods and measurement of thermodilution cardiac output.Nurs Res. 1993 Jul-Aug;42(4):228-33. Nurs Res. 1993. PMID: 8337161 Review.
Cited by
-
Effect of measurement errors on cardiac output calculated with O2 and modified CO2 Fick methods.J Clin Monit. 1995 Mar;11(2):99-108. doi: 10.1007/BF01617731. J Clin Monit. 1995. PMID: 7760094
-
Estimation of cardiac index by means of the arterial and the mixed venous oxygen content and pulmonary oxygen uptake determination in the early post-operative period following surgery of congenital heart disease.Intensive Care Med. 1994 Aug;20(7):500-3. doi: 10.1007/BF01711904. Intensive Care Med. 1994. PMID: 7995867
References
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources