Air contamination during total hip arthroplasty in an ultraclean air enclosure using different types of staff clothing
- PMID: 2358811
- DOI: 10.1016/s0883-5403(06)80231-7
Air contamination during total hip arthroplasty in an ultraclean air enclosure using different types of staff clothing
Abstract
Air contamination was measured in a down-flow, clean air enclosure during 50 total hip arthroplasties to compare the effect of different scrub suits and operating gowns. In one series, with cotton clothes, the operating gowns used were either disposable nonwoven operating gowns or total body exhaust gowns. With the exhaust gowns the median air contamination, measured as colony-forming units (cfu)/m3, was reduced by about 5 times, to 0.3. In another series, nonwoven operating gowns were used together with scrub suits made of either cotton or one of two types of synthetic materials. The latter two scrub suits were equipped with elastic sealings at the openings. With both of these types the median air contamination, compared to cotton scrub suits, was reduced by about one half, to 0.4 cfu/m3. The authors conclude that both specially designed scrub suits and exhaust gowns can further reduce an already low level of bacterial air contamination in a down-flow, clean air enclosure.
Similar articles
-
Lack of influence of body exhaust gowns on aerobic bacterial surface counts in a mixed-ventilation operating theatre. A study of 62 hip arthroplasties.J Hosp Infect. 2003 May;54(1):2-9. doi: 10.1016/s0195-6701(03)00077-x. J Hosp Infect. 2003. PMID: 12767840
-
Reduction of contamination at total hip replacement by special working clothes.J Bone Joint Surg Br. 1990 Nov;72(6):985-7. doi: 10.1302/0301-620X.72B6.2246302. J Bone Joint Surg Br. 1990. PMID: 2246302
-
Bacterial dispersion in relation to operating room clothing.J Hyg (Lond). 1976 Jun;76(3):367-78. doi: 10.1017/s0022172400055297. J Hyg (Lond). 1976. PMID: 778258 Free PMC article.
-
Do 'Surgical Helmet Systems' or 'Body Exhaust Suits' Affect Contamination and Deep Infection Rates in Arthroplasty? A Systematic Review.J Arthroplasty. 2016 Jan;31(1):225-33. doi: 10.1016/j.arth.2015.07.043. Epub 2015 Aug 1. J Arthroplasty. 2016. PMID: 26321627
-
Role of the environment of the operating suite in surgical wound infection.Rev Infect Dis. 1991 Sep-Oct;13 Suppl 10:S800-4. doi: 10.1093/clinids/13.supplement_10.s800. Rev Infect Dis. 1991. PMID: 1754788 Review.
Cited by
-
Sterility of the personal protection system in total joint arthroplasty.Clin Orthop Relat Res. 2011 Nov;469(11):3065-9. doi: 10.1007/s11999-011-1883-1. Clin Orthop Relat Res. 2011. PMID: 21671110 Free PMC article.
-
Surgical site infection risk factors and risk stratification.J Am Acad Orthop Surg. 2015 Apr;23 Suppl(Suppl):S8-S11. doi: 10.5435/JAAOS-D-14-00447. J Am Acad Orthop Surg. 2015. PMID: 25808971 Free PMC article.
-
Outcome following deep wound contamination in cemented arthroplasty.Int Orthop. 2007 Feb;31(1):27-31. doi: 10.1007/s00264-006-0121-z. Epub 2006 Apr 4. Int Orthop. 2007. PMID: 16586132 Free PMC article. Clinical Trial.
-
Periprosthetic joint infections at a teaching hospital in 1990-2007.Can J Surg. 2012 Dec;55(6):394-400. doi: 10.1503/cjs.033610. Can J Surg. 2012. PMID: 22992404 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical