. 2013 Oct;34(7):1645-51.
doi: 10.1007/s00246-013-0695-3. Epub 2013 Apr 17.

Impact of the Amplatzer atrial septal occluder device on left ventricular function in pediatric patients

Affiliations

Impact of the Amplatzer atrial septal occluder device on left ventricular function in pediatric patients

Biagio Castaldi et al. Pediatr Cardiol. 2013 Oct.

Abstract

Percutaneous closure currently is widely considered to be the first-choice therapeutic option in the treatment of ostium secundum atrial septal defect (ASD). The Amplatzer Septal Occluder (ASO) device is the most used prosthesis, although its influence on cardiac function still is under active investigation. This study aimed to evaluate the impact of the ASO device size on left ventricular (LV) function in pediatric patients using the speckle-tracking strain imaging technology. The study enrolled 43 nonobese pediatric patients submitted to percutaneous ASD closure with the Amplatzer Septal Occluder device and grouped them according to the size of the occluding prosthesis into three groups: a small-device group (≤ 10 mm, group 1), a medium-size-device group (11-16 mm, group 2), and a large-device group (≥ 17 mm, group 3). Echocardiographic data were compared among the groups and with the data of an age-, weight-, and gender-matched control group (50 patients). The large-device group showed a significant impairment in the strain rate value of the basal LV segments. In particular, the mean basal circumferential and radial strain rate values were lower than either normal or the values of the small- and medium-device groups. However, only the absolute device diameter reached statistical significance in the multivariate analysis. The large Amplatzer Septal Occluding device significantly impaired LV systolic function, particularly that of juxtaprosthetic segments, as shown in the strain rate analysis.

PubMed Disclaimer

Similar articles

Cited by

References

    1. JACC Cardiovasc Interv. 2012 Nov;5(11):1178-84 - PubMed
    1. Catheter Cardiovasc Interv. 2007 Feb 15;69(3):447-52 - PubMed
    1. Pediatr Cardiol. 2013 Feb;34(2):220-5 - PubMed
    1. J Thorac Cardiovasc Surg. 2007 Oct;134(4):960-6 - PubMed
    1. J Interv Cardiol. 2008 Aug;21(4):363-8 - PubMed

LinkOut - more resources