Device closure of interatrial communications: peri-interventional echocardiographic assessment
- PMID: 23598422
- DOI: 10.1093/ehjci/jet048
Device closure of interatrial communications: peri-interventional echocardiographic assessment
Abstract
The interventional closure of interatrial communications requires peri-interventional echocardiographic assessment and guidance to make those treatments as safe as possible. Transoesophageal echocardiography (TEE) including real-time three-dimensional (RT-3D) imaging, later complemented and in part replaced by intracardiac echocardiography (ICE), has become established as the standard approach to prepare for and to guide the interventional treatment of interatrial communications. Accurate imaging of the anatomic features of the particular communication is critical for case selection, planning, and intraprocedural guidance. Especially in the atrial septal defect (ASD) closure, which tends to be more challenging than the patent foramen ovale (PFO) closure, a certain risk of severe complications remains and may result from suboptimal device performance. Other complications may be related to discontinuous use of echocardiographic monitoring. Image fusion and RT-3D ICE are currently under clinical testing and might be suitable to facilitate spatial orientation. Nowadays, two-dimensional ICE is the method of choice for guiding percutaneous device closure, especially of ASDs and 'complex' PFOs. Uninterrupted TEE under deep sedation is an alternative. In contrast, the closure of 'simple' PFOs will often require nothing but final confirmation of the result, and therefore, short echocardiographic viewing is sufficient in many cases.
Similar articles
-
Contemporary echocardiographic guiding tools for device closure of interatrial communications.Cardiovasc Diagn Ther. 2013 Mar;3(1):38-46. doi: 10.3978/j.issn.2223-3652.2013.02.07. Cardiovasc Diagn Ther. 2013. PMID: 24282743 Free PMC article. Review.
-
Intracardiac echocardiography: an ideal guiding tool for device closure of interatrial communications.Eur J Echocardiogr. 2005 Mar;6(2):92-6. doi: 10.1016/j.euje.2004.07.007. Eur J Echocardiogr. 2005. PMID: 15760685 Clinical Trial.
-
Intracardiac echocardiography during atrial septal defect and patent foramen ovale device closure in pediatric and adolescent patients.J Am Soc Echocardiogr. 2014 Sep;27(9):984-90. doi: 10.1016/j.echo.2014.05.017. Epub 2014 Jul 4. J Am Soc Echocardiogr. 2014. PMID: 24998516
-
The relation between atrial septal defect shape, diameter, and area using three-dimensional transoesophageal echocardiography and balloon sizing during percutaneous closure in children.Eur Heart J Cardiovasc Imaging. 2015 Jul;16(7):747-55. doi: 10.1093/ehjci/jeu316. Epub 2015 Jan 23. Eur Heart J Cardiovasc Imaging. 2015. PMID: 25617028
-
Imaging Assessment of the Interatrial Septum for Transcatheter Atrial Septal Defect and Patent Foramen Ovale Closure.Interv Cardiol Clin. 2017 Oct;6(4):505-524. doi: 10.1016/j.iccl.2017.05.004. Interv Cardiol Clin. 2017. PMID: 28886842 Review.
Cited by
-
Early Diagnosis of Cardiovascular Diseases in Workers: Role of Standard and Advanced Echocardiography.Biomed Res Int. 2018 Jan 16;2018:7354691. doi: 10.1155/2018/7354691. eCollection 2018. Biomed Res Int. 2018. PMID: 29560362 Free PMC article. Review.
-
Forme Fruste Cor Triatriatum Dexter by Transesophageal Echocardiography and Its Impact on Percutaneous Heart Procedures: A Case Series.CASE (Phila). 2019 Jul 24;3(5):189-199. doi: 10.1016/j.case.2019.05.004. eCollection 2019 Oct. CASE (Phila). 2019. PMID: 31709369 Free PMC article.
-
Why is intracardiac echocardiography helpful? Benefits, costs, and how to learn.Eur Heart J. 2014 Jan;35(2):69-76. doi: 10.1093/eurheartj/eht411. Epub 2013 Oct 21. Eur Heart J. 2014. PMID: 24144789 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources