Fast immunosensing technique to detect Legionella pneumophila in different natural and anthropogenic environments: comparative and collaborative trials
- PMID: 23601924
- PMCID: PMC3637370
- DOI: 10.1186/1471-2180-13-88
Fast immunosensing technique to detect Legionella pneumophila in different natural and anthropogenic environments: comparative and collaborative trials
Abstract
Background: Legionellosis is an uncommon form of pneumonia. After a clinical encounter, the necessary antibiotic treatment is available if the diagnosis is made early in the illness. Before the clinical encounter, early detection of the main pathogen involved, Legionella pneumophila, in hazardous environments is important in preventing infectious levels of this bacterium. In this study a qualitative test based on combined magnetic immunocapture and enzyme-immunoassay for the fast detection of Legionella pneumophila in water samples was compared with the standard method, in both comparative and collaborative trials. The test was based on the use of anti-Legionella pneumophila antibodies immobilized on magnetic microspheres. The final protocol included concentration by filtration, resuspension and immunomagnetic capture. The whole assay took less than 1 hour to complete.
Results: A comparative trial was performed against the standard culture method (ISO 11731) on both artificially and naturally contaminated water samples, for two matrices: chlorinated tap water and cooling tower water. Performance characteristics of the test used as screening with culture confirmation resulted in sensitivity, specificity, false positive, false negative, and efficiency of 96.6%, 100%, 0%, 3.4%, and 97.8%, respectively. The detection limit at the level under which the false negative rate increases to 50% (LOD50) was 93 colony forming units (CFU) in the volume examined for both tested matrices. The collaborative trial included twelve laboratories. Water samples spiked with certified reference materials were tested. In this study the coincidence level between the two methods was 95.8%.
Conclusion: Results demonstrate the applicability of this immunosensing technique to the rapid, simple, and efficient detection of Legionella pneumophila in water samples. This test is not based on microbial growth, so it could be used as a rapid screening technique for the detection of L. pneumophila in waters, maintaining the performance of conventional culture for isolation of the pathogen and related studies.
Similar articles
-
Method modification of the Legipid® Legionella fast detection test kit.J AOAC Int. 2014 Sep-Oct;97(5):1403-9. doi: 10.5740/jaoacint.14-029. J AOAC Int. 2014. PMID: 25902991
-
Validation of the Legipid bioalarm Legionella assay.J AOAC Int. 2012 Sep-Oct;95(5):1440-51. doi: 10.5740/jaoacint.12-146. J AOAC Int. 2012. PMID: 23175978
-
Evaluation of a Legionella urinary antigen enzyme immunoassay for rapid detection of Legionella pneumophila in water samples.Int J Hyg Environ Health. 2008 Mar;211(1-2):168-71. doi: 10.1016/j.ijheh.2007.02.002. Epub 2007 Mar 27. Int J Hyg Environ Health. 2008. PMID: 17392021
-
Microbiological investigations on a nosocomial case of Legionella pneumophila pneumonia associated with water birth and review of neonatal cases.Infez Med. 2004 Mar;12(1):69-75. Infez Med. 2004. PMID: 15329532 Review.
-
Overview of the Clinical and Molecular Features of Legionella Pneumophila: Focus on Novel Surveillance and Diagnostic Strategies.Antibiotics (Basel). 2022 Mar 9;11(3):370. doi: 10.3390/antibiotics11030370. Antibiotics (Basel). 2022. PMID: 35326833 Free PMC article. Review.
Cited by
-
Water Sampling Module for Collecting and Concentrating Legionella pneumophila from Low-to-Medium Contaminated Environment.Biosensors (Basel). 2021 Jan 27;11(2):34. doi: 10.3390/bios11020034. Biosensors (Basel). 2021. PMID: 33513950 Free PMC article.
-
Graphene oxide/Cu-MOF-based electrochemical immunosensor for the simultaneous detection of Mycoplasma pneumoniae and Legionella pneumophila antigens in water.Sci Rep. 2024 Jul 26;14(1):17172. doi: 10.1038/s41598-024-68231-y. Sci Rep. 2024. PMID: 39060466 Free PMC article.
-
Methodological approaches for monitoring opportunistic pathogens in premise plumbing: A review.Water Res. 2017 Jun 15;117:68-86. doi: 10.1016/j.watres.2017.03.046. Epub 2017 Mar 25. Water Res. 2017. PMID: 28390237 Free PMC article. Review.
-
Immunomagnetic separation coupled with flow cytometry for the analysis of Legionella pneumophila in aerosols.Anal Bioanal Chem. 2023 Sep;415(21):5139-5149. doi: 10.1007/s00216-023-04738-z. Epub 2023 May 18. Anal Bioanal Chem. 2023. PMID: 37204446 Free PMC article.
-
Current and emerging Legionella diagnostics for laboratory and outbreak investigations.Clin Microbiol Rev. 2015 Jan;28(1):95-133. doi: 10.1128/CMR.00029-14. Clin Microbiol Rev. 2015. PMID: 25567224 Free PMC article. Review.
References
-
- Yu VL, Plouffe JF, Pastoris MC, Stout JE, Schousboe M, Widmer A, Summersgill J, File T, Heath CM, Paterson DL, Chereshsky A. Distribution of Legionella species and serogroups isolated by culture in patients with sporadic community- acquired pneumonia: an international collaborative survey. J Infect Dis. 2002;186:127–128. doi: 10.1086/341087. - DOI - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Molecular Biology Databases
Miscellaneous