Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2013 Jun;51(6):529-36.
doi: 10.5414/CP201806.

Relative bioavailability of a newly developed pediatric formulation of bosentan vs. the adult formulation

Affiliations
Randomized Controlled Trial

Relative bioavailability of a newly developed pediatric formulation of bosentan vs. the adult formulation

Marcelo M Gutierrez et al. Int J Clin Pharmacol Ther. 2013 Jun.

Abstract

What is known: Bosentan is a dual endothelin receptor antagonist approved for the treatment of pulmonary arterial hypertension (PAH). Since bosentan is frequently used to treat pediatric PAH patients, a pediatric formulation was developed.

Aim: To evaluate the pharmacokinetic properties of bosentan and its active metabolite, Ro 48-5033, of the quadrisected, dispersible pediatric vs. the adult tablet after single-dose administration to healthy subjects. Secondary objectives of the study were to compare the pharmacokinetics of two inactive metabolites and the safety of both formulations.

Materials and methods: In this open-label, two-way crossover study, subjects (20 - 43 years) were randomized to receive single oral doses of 62.5 mg of bosentan as 1 adult tablet and 64 mg as 2 pediatric tablets of 32 mg. Blood samples were drawn over a 48-hour period to measure bosentan and its metabolites.

Results: 16 subjects were enrolled and completed the study. Following treatment with the pediatric formulation, values for Cmax and AUC0-∞ of bosentan were lower than with the adult formulation with geometric mean ratios (90% confidence interval) of 0.82 (0.65, 1.04) and 0.87 (0.78, 0.97), respectively. Similar results were obtained for the primary active metabolite Ro 48-5033. Both treatments were well tolerated.

What is new and conclusion: Although the 90% confidence intervals of the geometric mean ratios of Cmax and AUC0-∞ were not entirely within the conventional bioequivalence range (0.80 - 1.25), no clinically relevant effect of formulation on the pharmacokinetics of bosentan and Ro 48-5033 was detected. Both formulations were well tolerated.

PubMed Disclaimer

Publication types

MeSH terms