Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 May 15:109:61-73.
doi: 10.1016/j.talanta.2013.01.058. Epub 2013 Feb 14.

Determination of uptake kinetics and sampling rates for 56 organic micropollutants using "pharmaceutical" POCIS

Affiliations

Determination of uptake kinetics and sampling rates for 56 organic micropollutants using "pharmaceutical" POCIS

Nicolas Morin et al. Talanta. .

Abstract

The literature increasingly reports sampling rates (Rs) for Polar Organic Chemical Integrative Samplers (POCIS) but the data obtained come from various calibration systems that are not always well-defined (agitation, temperature, measured micropollutant concentrations in water,…). In order to obtain accurate laboratory Rs for priority and emerging substances, POCIS need to be exposed in a robust and well-defined calibration system. Thus, we built a flow-through calibration system containing tap water spiked with 56 organic micropollutants (alkylphenols and phenols, hormones, pesticides, pharmaceuticals, UV filter). POCIS were immersed for up to 28 days. Tap water micropollutant concentrations and additional parameters (temperature, pH, conductivity, dissolved organic carbon, flow velocities) were kept constant and controlled throughout the calibration experiment. Based on the observed uptake kinetics, we distinguished four types of micropollutant accumulation patterns: curvilinear accumulation (30 molecules, group 1), accumulation with an inflexion point (13 molecules, group 2), random accumulation (eight molecules, group 3), and no or very low accumulation (five molecules, group 4). Rs was calculated for 43 out of 56 micropollutants (groups 1 and 2). Calculated Rs values ranged from 0.030 L/d to 0.398 L/d. POCIS can supply TWA concentrations for hormones, pesticides, several pharmaceuticals, a few alkylphenols, and the UV filter. Our Rs results are generally less than two fold-different (higher or lower depending on target molecule) to the literature data using the same type of calibration system or for micropollutants with log Kow>2.65. We found a quadratic correlation between Rs and log D for betablockers, herbicides and hormones.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

Substances

LinkOut - more resources