Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2014 Mar;26(2):192-9.
doi: 10.1111/den.12117. Epub 2013 Apr 29.

Placement of a triple-layered covered versus uncovered metallic stent for palliation of malignant gastric outlet obstruction: a multicenter randomized trial

Affiliations
Randomized Controlled Trial

Placement of a triple-layered covered versus uncovered metallic stent for palliation of malignant gastric outlet obstruction: a multicenter randomized trial

Iruru Maetani et al. Dig Endosc. 2014 Mar.

Abstract

Background: Usually, uncovered self-expandable metallic stents (SEMS) are used for palliation of malignant gastric outlet obstruction (GOO). A triple-layered covered SEMS is reported to be efficacious, but its performance has not been compared with uncovered SEMS. The present study is the first to compare the efficacy and safety of a triple-layered covered versus uncovered SEMS.

Patients and methods: A multicenter randomized study was conducted in two tertiary referral centers, with 62 eligible patients with symptomatic GOO to receive covered (n = 31) or uncovered SEMS (n = 31). The primary endpoint was SEMS patency, and secondary endpoints were success rate and adverse events after complete follow up.

Results: Both groups had a technical success rate of 100% and comparable clinical success rates (P = 0.67). There was nostatistically significant difference in stent patency and adverse events between the two groups (P = 0.52 and P = 0.38, respectively). Although the occurrence rate of persistent obstructive symptoms was comparable (P = 0.42), that of recurrent obstructive symptoms was higher in the uncovered group (29% vs 3.6%, P = 0.0125). Patient survival did not differ between groups (P = 0.34).

Conclusion: There was no statistically significant difference in stent patency, but use of a triple-layered covered SEMS was associated with less frequent stent dysfunction more than 4 weeks after stenting, despite similar short-term outcomes.

Keywords: covered stent; gastric outlet obstruction (GOO); self-expandable metallic stent (SEMS); uncovered stent.