Methods for assessing the adequacy of practice and improving room disinfection
- PMID: 23622743
- DOI: 10.1016/j.ajic.2013.01.003
Methods for assessing the adequacy of practice and improving room disinfection
Abstract
The value of objectively monitoring and improving environmental cleaning in health care settings is becoming increasingly recognized as an important component of interventions to mitigate the transmission of health care-associated pathogens. Whereas the 2010 Centers for Disease Control and Prevention tool kit "Options for Evaluating Environmental Cleaning" provides detailed guidance related to implementing such programs, there is a need to clearly understand the value and limitations of various environmental cleaning monitoring approaches to ensure the favorable impact of such activities.
Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Similar articles
-
Breaking the chain: Strategies for effective terminal cleaning.Health Facil Manage. 2014 Apr;27(4):45-7. Health Facil Manage. 2014. PMID: 24830136 No abstract available.
-
Best practices in disinfection of noncritical surfaces in the health care setting: creating a bundle for success.Am J Infect Control. 2013 May;41(5 Suppl):S26-30. doi: 10.1016/j.ajic.2012.10.028. Am J Infect Control. 2013. PMID: 23622744 Review.
-
Evaluating accuracy of sampling strategies for fluorescent gel monitoring of patient room cleaning.Infect Control Hosp Epidemiol. 2019 Jul;40(7):794-797. doi: 10.1017/ice.2019.102. Infect Control Hosp Epidemiol. 2019. PMID: 31172902 Free PMC article.
-
Disinfectants used for environmental disinfection and new room decontamination technology.Am J Infect Control. 2013 May;41(5 Suppl):S36-41. doi: 10.1016/j.ajic.2012.11.006. Am J Infect Control. 2013. PMID: 23622746 Review.
-
Does improving surface cleaning and disinfection reduce health care-associated infections?Am J Infect Control. 2013 May;41(5 Suppl):S12-9. doi: 10.1016/j.ajic.2012.12.010. Epub 2013 Mar 7. Am J Infect Control. 2013. PMID: 23465603 Review.
Cited by
-
Fluorescent Marker as a Tool to Improve Strategies to Control Contaminated Surfaces and Decrease Danger of Cross-Contamination in Dental Clinics, during and beyond the COVID-19 Pandemic.Int J Environ Res Public Health. 2023 Mar 22;20(6):5229. doi: 10.3390/ijerph20065229. Int J Environ Res Public Health. 2023. PMID: 36982137 Free PMC article.
-
What Healthcare Workers Should Know about Environmental Bacterial Contamination in the Intensive Care Unit.Biomed Res Int. 2017;2017:6905450. doi: 10.1155/2017/6905450. Epub 2017 Oct 29. Biomed Res Int. 2017. PMID: 29214175 Free PMC article. Review.
-
Is the combination of UV-C light and bleach less effective than bleach alone for intensive care unit surface disinfection?Infect Prev Pract. 2023 Sep 12;5(4):100307. doi: 10.1016/j.infpip.2023.100307. eCollection 2023 Dec. Infect Prev Pract. 2023. PMID: 38107241 Free PMC article.
-
Improving hospital-based point-of-care ultrasound cleaning practices using targeted interventions: a pre-post study.Ultrasound J. 2021 Oct 18;13(1):43. doi: 10.1186/s13089-021-00244-4. Ultrasound J. 2021. PMID: 34664118 Free PMC article.
-
Tolerance of clinical vancomycin-resistant Enterococcus faecium isolates against UV-C light from a mobile source.Antimicrob Resist Infect Control. 2023 Jul 4;12(1):63. doi: 10.1186/s13756-023-01259-3. Antimicrob Resist Infect Control. 2023. PMID: 37403134 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical