The ruptured PIP breast implant
- PMID: 23622796
- DOI: 10.1016/j.crad.2013.03.012
The ruptured PIP breast implant
Abstract
Public concern erupted about the safety of Poly Implant Prothèse (PIP) breast implants when it was revealed in 2011 that they contained an inferior, unlicensed industrial-grade silicone associated with a high rate of rupture. There followed national guidance for UK clinicians, which led to a considerable increase in referrals of asymptomatic women for breast implant assessment. In this review we discuss possible approaches to screening the PIP cohort and the salient characteristics of a ruptured implant.
Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Similar articles
-
Ultrasonography is more useful in assessment of suspected breast implant infections rather than capsular contracture.Ann Plast Surg. 2006 Oct;57(4):477-8. doi: 10.1097/01.sap.0000233064.47244.02. Ann Plast Surg. 2006. PMID: 16998351 No abstract available.
-
Ultrasonographic appearance of breast implant complications.Ann Plast Surg. 2006 Mar;56(3):243-7. doi: 10.1097/01.sap.0000198560.24518.e7. Ann Plast Surg. 2006. PMID: 16508351 No abstract available.
-
PIP implant biodurability: a post-publicity update.J Plast Reconstr Aesthet Surg. 2013 Sep;66(9):1174-81. doi: 10.1016/j.bjps.2013.04.050. Epub 2013 May 10. J Plast Reconstr Aesthet Surg. 2013. PMID: 23668948
-
The sonographic appearances of breast implant rupture.Clin Radiol. 2013 Aug;68(8):851-8. doi: 10.1016/j.crad.2013.03.014. Epub 2013 Apr 24. Clin Radiol. 2013. PMID: 23623260 Review.
-
The diagnosis of silicone breast implant rupture.Plast Reconstr Surg. 2007 Dec;120(7 Suppl 1):49S-61S. doi: 10.1097/01.prs.0000286569.45745.6a. Plast Reconstr Surg. 2007. PMID: 18090814 Review.
Cited by
-
Comparative Study Between Breast Implants and Adipose Tissue Autograft in Primary Aesthetic Breast Augmentation.Aesthetic Plast Surg. 2025 Jun 2. doi: 10.1007/s00266-025-04922-9. Online ahead of print. Aesthetic Plast Surg. 2025. PMID: 40456993
-
MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard.Eur Radiol. 2014 Jun;24(6):1167-75. doi: 10.1007/s00330-014-3119-8. Epub 2014 Mar 6. Eur Radiol. 2014. PMID: 24599622 Clinical Trial.
-
On the universality of medical device regulations: the case of Benin.BMC Health Serv Res. 2022 Aug 12;22(1):1031. doi: 10.1186/s12913-022-08396-2. BMC Health Serv Res. 2022. PMID: 35962389 Free PMC article.
-
Poly Implant Prothèse (PIP) incidence of rupture: a retrospective MR analysis in 64 patients.Quant Imaging Med Surg. 2014 Dec;4(6):462-8. doi: 10.3978/j.issn.2223-4292.2014.08.01. Quant Imaging Med Surg. 2014. PMID: 25525578 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical