Comparative Study
. 2013 Sep;23(9):2628-35.
doi: 10.1007/s00330-013-2838-6. Epub 2013 Apr 28.

Comparative diagnostic accuracy of contrast-enhanced MRI and (18)F-FDOPA PET-CT in recurrent glioma

Affiliations
Comparative Study

Comparative diagnostic accuracy of contrast-enhanced MRI and (18)F-FDOPA PET-CT in recurrent glioma

Sellam Karunanithi et al. Eur Radiol. 2013 Sep.

Abstract

Objectives: To compare the diagnostic accuracy of contrast enhanced magnetic resonance imaging (Ce-MRI) and (18)F-fluorodopa ((18)F-FDOPA) positron emission tomography (PET)-computed tomography (CT) for detecting recurrent glioma.

Methods: In this prospective study, 35 patients (age, 36.62 ± 0.86 years; 80 % male) with histopathologically proven glioma with clinical suspicion of recurrence were evaluated using Ce-MRI and (18)F-FDOPA PET-CT. (18)F-FDOPA PET-CT images were evaluated qualitatively and semi-quantitatively. Combination of clinical follow-up (minimum 1 year), repeat imaging and/or biopsy (when available) was taken as the reference standard.

Results: Based on the reference standard, 26 patients were positive and nine were negative for recurrence. The sensitivity, specificity and accuracy of Ce-MRI were 92.3 %, 44.4 % and 80 % respectively, whereas those of (18)F-FDOPA PET-CT were 100 %, 88.89 % and 97.1 % respectively. Results of Ce-MRI and (18)F-FDOPA PET-CT were concordant in 74.3 % (29/35) and discordant in 17.1 % of patients (6/35). On McNemar analysis the difference was not statistically significant overall (P = 0.687), for high-grade tumour (P = 0.5) or low-grade tumours (P = 1.0). However, (18)F-FDOPA PET-CT was more specific than Ce-MRI overall (P = 0.0002), for high-grade tumour (P = 0.006) and low-grade tumours (P = 0.004).

Conclusion: F-FDOPA PET-CT shows a high but comparable diagnostic accuracy to Ce-MRI for the detection of recurrent glioma. However, it is more specific than Ce-MRI.

Key points: • Recurrent glioma in the postoperative site remains a diagnostic dilemma. • (18) F-FDOPA PET-CT shows high diagnostic accuracy for detecting recurrent glioma. • Diagnostic accuracies for (18) F-FDOPA PET-CT and contrast enhanced MRI are comparable. • However, (18) F-FDOPA PET-CT is more specific than Ce-MRI for recurrent glioma.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Radiat Med. 1995 Jan-Feb;13(1):11-7 - PubMed
    1. S Afr Med J. 1978 Feb 4;53(5):171-2 - PubMed
    1. J Nucl Med. 2010 Oct;51(10):1532-8 - PubMed
    1. Nucl Med Rev Cent East Eur. 2002;5(2):127-30 - PubMed
    1. Semin Nucl Med. 2012 Nov;42(6):356-70 - PubMed

Publication types

MeSH terms