The value of observer performance studies in dose optimization: a focus on free-response receiver operating characteristic methods
- PMID: 23625536
- DOI: 10.2967/jnmt.112.116566
The value of observer performance studies in dose optimization: a focus on free-response receiver operating characteristic methods
Erratum in
- J Nucl Med Technol. 2014 Mar;42(1):10A
Abstract
Receiver operating characteristic (ROC) analysis has been successfully used in radiology to help determine the combined success of system and observer. There is great value in these methods for assessing new and existing techniques to see if diagnostic accuracy can be improved. Within all aspects of radiology there should be compliance with the as-low-as-reasonably-achievable principle, which requires optimization of the diagnostic suitability of the image. Physical measures of image quality have long been used in the assessment of system performance, but these alone are not sufficient to assess diagnostic capability. It is imperative that the observer be included in any assessment of diagnostic performance. The free-response ROC paradigm has been developed as a statistically powerful advancement of traditional ROC analysis that allows a precise interpretation of complex images by adding location information to the level of observer confidence. The following review of free-response ROC methodology will explain how observer performance methods can be valuable in image optimization, including examples of how these have already been successful in hybrid imaging.
Keywords: FROC; observer performance; optimization.
Similar articles
-
Recent advances in observer performance methodology: jackknife free-response ROC (JAFROC).Radiat Prot Dosimetry. 2005;114(1-3):26-31. doi: 10.1093/rpd/nch512. Radiat Prot Dosimetry. 2005. PMID: 15933077
-
Free-response methodology: alternate analysis and a new observer-performance experiment.Radiology. 1990 Mar;174(3 Pt 1):873-81. doi: 10.1148/radiology.174.3.2305073. Radiology. 1990. PMID: 2305073
-
[Performance assessment of mammographic diagnostic systems: evolution of methods and their application to a digital image study].Radiol Med. 1999 Mar;97(3):179-87. Radiol Med. 1999. PMID: 10363062 Italian.
-
Receiver operating characteristic analysis: a tool for the quantitative evaluation of observer performance and imaging systems.J Am Coll Radiol. 2006 Jun;3(6):413-22. doi: 10.1016/j.jacr.2006.02.021. J Am Coll Radiol. 2006. PMID: 17412096 Review.
-
Visual perception studies and observer models in medical imaging.Semin Nucl Med. 2011 Nov;41(6):419-36. doi: 10.1053/j.semnuclmed.2011.06.005. Semin Nucl Med. 2011. PMID: 21978445 Review.
Cited by
-
A simple method for low-contrast detectability, image quality and dose optimisation with CT iterative reconstruction algorithms and model observers.Eur Radiol Exp. 2017;1(1):18. doi: 10.1186/s41747-017-0023-4. Epub 2017 Oct 23. Eur Radiol Exp. 2017. PMID: 29708194 Free PMC article.
-
Evaluation of Pseudoreader Study Designs to Estimate Observer Performance Results as an Alternative to Fully Crossed, Multireader, Multicase Studies.Acad Radiol. 2020 Feb;27(2):244-252. doi: 10.1016/j.acra.2019.03.014. Epub 2019 May 7. Acad Radiol. 2020. PMID: 31076331 Free PMC article.
-
An Investigation of Lesion Detection Accuracy for Artificial Intelligence-Based Denoising of Low-Dose 64Cu-DOTATATE PET Imaging in Patients with Neuroendocrine Neoplasms.J Nucl Med. 2023 Jun;64(6):951-959. doi: 10.2967/jnumed.122.264826. Epub 2023 May 11. J Nucl Med. 2023. PMID: 37169532 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources