Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Jul;156(1):89-94.e1.
doi: 10.1016/j.ajo.2013.02.003. Epub 2013 Apr 28.

Ocular biometric parameters associated with intraocular pressure reduction after cataract surgery in normal eyes

Affiliations

Ocular biometric parameters associated with intraocular pressure reduction after cataract surgery in normal eyes

Hyun Seung Yang et al. Am J Ophthalmol. 2013 Jul.

Abstract

Purpose: To evaluate the ocular biometric parameters associated with intraocular pressure (IOP) reduction after phacoemulsification.

Design: Prospective, observational case series.

Methods: The study included 999 patients who had undergone uncomplicated phacoemulsification. IOP and ocular biometric parameters were checked preoperatively and 3 months postoperatively using anterior segment optical coherence tomography, optical biometry, and ultrasonic biomicroscopy. The relationship between IOP change and the parameters, including preoperative IOP, anterior chamber depth, axial length, angle opening distance at 500 μm, anterior chamber area, corneal thickness, lens thickness, and iris thickness at 750 μm, was evaluated.

Results: The mean patient age was 67.1 ± 4.3 years. The average change in IOP was -1.6 mm Hg (-11.8%). In univariate analysis, axial length, corneal thickness, and iris thickness were not significantly associated with IOP reduction. However, preoperative IOP, anterior chamber depth, angle opening distance, anterior chamber area, and lens thickness were significantly associated with IOP change (P < .05). Furthermore, changes in anterior chamber depth (standardized coefficient beta [B] = -0.082), angle opening distance (B = -0.095), and anterior chamber area (B = -0.380) were more strongly correlated with IOP change than were preoperative factors (B = -0.078, B = -0.071, and B = -0.067, respectively). In multivariate analysis, preoperative IOP, lens thickness, angle opening distance change, and anterior chamber area change were significantly associated with IOP change (P < .005).

Conclusion: In addition to preoperative IOP and lens thickness, parameters such as changes in anterior chamber area and angle opening distance were significantly associated positively with reduced IOP after phacoemulsification.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

LinkOut - more resources