Optical biometry intraocular lens power calculation using different formulas in patients with different axial lengths

Affiliations

Optical biometry intraocular lens power calculation using different formulas in patients with different axial lengths

Jia-Kang Wang et al. Int J Ophthalmol. .

Abstract

Aim: : To investigate the predictability of intraocular lens (IOL) power calculation using the IOLMaster and different IOL power calculation formulas in eyes with various axial length (AL).

Methods: : Patients were included who underwent uneventful phacoemulsification with IOL implantation in the Department of Ophthalmology, Far Eastern Memorial Hospital, Taipei, Taiwan, China from February 2007 to January 2009. Preoperative AL and keratometric values (Ks) were measured by IOLMaster optical biometry. Patients were divided into 3 groups based on AL less than 22mm (Group 1), 22-26mm (Group 2), and more than 26mm (Group 3). The power of the implanted IOL was used to calculate the predicted postoperative spherical equivalence (SE) by various formulas: the Haigis, Hoffer Q, Holladay 1, and SRK/T. The predictive accuracy of each formula was analyzed by comparing the difference between the actual and predicted postoperative SE (MedAE, median absolute error). All the patients had follow-up periods exceeding 3 months.

Results: : Totally, there were 200 eyes (33 eyes in Group 1, 92 eyes in Group 2, 75 eyes in Group 3). In all patients, the Haigis had the significantly lower MedAE generated by the other formulas (P<0.05). In Group 1 to 3, the MedAE calculated by the Haigis was either significantly lower or comparable to those calculated by the other formulas.

Conclusion: : Compared with other formulas using IOLMaster biometric data, the Haigis formula yields superior refractive results in eyes with various AL.

Keywords: calculation formula; intraocular lens; optical biometry.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Drexler W, Findl O, Menapace R, Rainer G, Vass C, Hitzenberger CK, Fercher AF. Partial coherence interferometry: a novel approach to biometry in cataract surgery. Am J Ophthalmol. 1998;126(4):524–534. - PubMed
    1. Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 1992;18(2):125–129. - PubMed
    1. Findle O. Biometry and intraocular lens power calculation. Curr Opin Ophthalmol. 2005;16(1):61–61. - PubMed
    1. Findl O, Kriechbaum K, Sacu S, Kiss B, Polak K, Nepp J, Schild G, Rainer G, Maca S, Petternel V, Lackner B, Drexler W. Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery. J Cataract Refract Surg. 2003;29(10):1950–1955. - PubMed
    1. Aristodemou P, Knox Cartwright NE, Sparrow JM, Johnston RL. Formula choice: Hoffer Q, Holladay 1, or SRK/T, and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry. J Cataract Refract Surg. 2011;37(1):63–71. - PubMed

LinkOut - more resources