Interval estimation of the LD50 based on an up-and-down experiment
- PMID: 2364133
Interval estimation of the LD50 based on an up-and-down experiment
Abstract
It is well known that an up-and-down method can be more efficient than fixed-sample methods in estimating the LD50 of a quantal response curve. A problem that has not been addressed by many is that of obtaining a confidence interval for the LD50 from the up-and-down method. Dixon and Mood (1948, Journal of the American Statistical Association 43, 109-126) proposed a confidence interval using a maximum likelihood approach, but not much is known about its properties. In this paper, a new confidence interval for the LD50 based on turning points is obtained, which uses the concept of phi-mixing. Simulation results indicate that the coverage probabilities of both methods tend to be less than the nominal level unless the sample size is large. Even so, when the tolerance distribution is normal, the proposed confidence interval is found to be superior to Dixon's interval in terms of the coverage, the width, and stability. The advantages of the method do not appear to hold in the presence of nonnormal tolerance distribution.
Similar articles
-
Kernel estimates of dose response.Biometrics. 1988 Dec;44(4):1103-19. Biometrics. 1988. PMID: 3233249
-
Sequential method of estimating the LD50 using a modified up-and-down rule.J Biopharm Stat. 1994 Mar;4(1):19-30. doi: 10.1080/10543409408835069. J Biopharm Stat. 1994. PMID: 8019581
-
Efficient design for estimation of median lethal dose and quantal dose-response curves.Biometrics. 1990 Sep;46(3):737-48. Biometrics. 1990. PMID: 2242412
-
Interval estimation of inverse dose-response.Biometrics. 1995 Jun;51(2):491-501. Biometrics. 1995. PMID: 7662838
-
Estimation of a parameter and its exact confidence interval following sequential sample size reestimation trials.Biometrics. 2004 Dec;60(4):910-8. doi: 10.1111/j.0006-341X.2004.00246.x. Biometrics. 2004. PMID: 15606411
Cited by
-
Does an Earlier or Late Intravenous Injection of Ondansetron Affect the Dose of Phenylephrine Needed to Prevent Spinal-Anesthesia Induced Hypotension in Cesarean Sections?Drug Des Devel Ther. 2020 Jul 16;14:2789-2795. doi: 10.2147/DDDT.S257880. eCollection 2020. Drug Des Devel Ther. 2020. PMID: 32764878 Free PMC article. Clinical Trial.
-
Optimized Planning and Evaluation of Dental Implant Fatigue Testing: A Specific Software Application.Biology (Basel). 2020 Oct 31;9(11):372. doi: 10.3390/biology9110372. Biology (Basel). 2020. PMID: 33142807 Free PMC article. Review.
-
Application of isotonic regression in estimating EDg and its 95% confidence interval by bootstrap method for a biased coin up-and-down sequential dose-finding design.Indian J Anaesth. 2023 Sep;67(9):828-831. doi: 10.4103/ija.ija_431_23. Epub 2023 Sep 6. Indian J Anaesth. 2023. PMID: 37829784 Free PMC article. No abstract available.
-
Optimal single-dose epidural neostigmine for postoperative analgesia after partial hepatectomy.Indian J Pharmacol. 2014 Nov-Dec;46(6):613-6. doi: 10.4103/0253-7613.144918. Indian J Pharmacol. 2014. PMID: 25538332 Free PMC article. Clinical Trial.
-
A randomized controlled trial of the effect of preoperative dexmedetomidine on the half maximal effective concentration of propofol for successful i-gel insertion without muscle relaxants.J Anesth. 2015 Jun;29(3):338-345. doi: 10.1007/s00540-014-1949-9. Epub 2014 Nov 14. J Anesth. 2015. PMID: 25394762 Clinical Trial.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources