Comparison of normal and keratoconic corneas by Galilei Dual-Scheimpflug Analyzer
- PMID: 23642799
- DOI: 10.1016/j.clae.2013.04.001
Comparison of normal and keratoconic corneas by Galilei Dual-Scheimpflug Analyzer
Abstract
Background and objective: To determine the efficacy of different Galilei Scheimpflug-Analyzer (GSA) parameters in discriminating between keratoconic and myopic eyes.
Patients and methods: GSA measurements were obtained for 67 patients (67 eyes) with keratoconus and 151 patients (151 eyes) with myopia or myopic astigmatism. Several parameters, provided by the software or derived from the elevation maps, were evaluated and compared for the two groups.
Results: Between the two groups, statistically significant differences were observed for all corneal parameters obtained by GSA (P<0.001) except for the anterior chamber depth (P=0.149). ROC analysis determined that posterior corneal elevation was the best predictive parameter (area under the curve: 0.99). The posterior corneal elevation, at a cut-off value of 18.5μm, had 98.5% sensitivity and 98.3% specificity in discriminating keratoconus from myopic eyes.
Conclusion: Elevation, pachymetric and keratometric parameters measured by the GSA, as well as the specific predictive GSA software parameters can effectively distinguish advanced keratoconus from myopic corneas. Also, keratoconus that is easily diagnosed by other means can be diagnosed easily by GSA software parameters.
Keywords: Anterior segment imaging; Clinical examination; Galilei; Keratoconus; Scheimpflug.
Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Similar articles
-
Evaluation of keratometric, pachymetric, and elevation parameters of keratoconic corneas with pentacam.Cornea. 2009 Oct;28(9):976-80. doi: 10.1097/ICO.0b013e31819e34de. Cornea. 2009. PMID: 19724217
-
Influence of the reference surface shape for discriminating between normal corneas, subclinical keratoconus, and keratoconus.J Refract Surg. 2013 Apr;29(4):274-81. doi: 10.3928/1081597X-20130318-07. J Refract Surg. 2013. PMID: 23557226
-
Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis.Br J Ophthalmol. 2013 Dec;97(12):1554-9. doi: 10.1136/bjophthalmol-2013-303477. Epub 2013 Sep 30. Br J Ophthalmol. 2013. PMID: 24081501 Clinical Trial.
-
[Corneal topography and keratoconus diagnostics with Scheimpflug photography].Ophthalmologe. 2014 Oct;111(10):920-6. doi: 10.1007/s00347-013-2962-3. Ophthalmologe. 2014. PMID: 25278345 Review. German.
-
Biomechanical properties of the keratoconic cornea: a review.Clin Exp Optom. 2015 Jan;98(1):31-8. doi: 10.1111/cxo.12211. Clin Exp Optom. 2015. PMID: 25545947 Review.
Cited by
-
Galilei Corneal Tomography for Screening of Refractive Surgery Candidates: A Review of the Literature, Part II.Med Hypothesis Discov Innov Ophthalmol. 2019 Fall;8(3):204-218. Med Hypothesis Discov Innov Ophthalmol. 2019. PMID: 31598521 Free PMC article. Review.
-
Changes in Corneal Morphology and Biomechanics in Cases of Small Incision Lenticule Extraction with Prophylactic Accelerated Collagen Cross-Linking.J Ophthalmol. 2022 Jul 11;2022:1640249. doi: 10.1155/2022/1640249. eCollection 2022. J Ophthalmol. 2022. PMID: 35859778 Free PMC article.
-
Comparison of anterior segment measurements obtained by three different devices in healthy eyes.Biomed Res Int. 2014;2014:498080. doi: 10.1155/2014/498080. Epub 2014 Jun 2. Biomed Res Int. 2014. PMID: 24987687 Free PMC article. Clinical Trial.
-
Clinical evaluation of ocular biometry of dual Scheimpflug analyzer, GALILEI G6 and swept source optical coherence tomography, ANTERION.Sci Rep. 2022 Mar 4;12(1):3602. doi: 10.1038/s41598-022-07696-1. Sci Rep. 2022. PMID: 35246594 Free PMC article.
-
Comparison of Anterior Chamber Depth between Normal and Keratoconic Eyes: A Systematic Review and Meta-Analysis.J Curr Ophthalmol. 2020 Mar 23;32(1):94-98. doi: 10.1016/j.joco.2019.01.010. eCollection 2020 Jan-Mar. J Curr Ophthalmol. 2020. PMID: 32510020 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical