Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Jul-Aug;27(4):782-90.
doi: 10.1111/jvim.12089. Epub 2013 May 6.

A single sample method for estimating glomerular filtration rate in cats

Affiliations
Free article

A single sample method for estimating glomerular filtration rate in cats

N C Finch et al. J Vet Intern Med. 2013 Jul-Aug.
Free article

Abstract

Background: Validated methods of estimating glomerular filtration rate (GFR) in cats requiring only a limited number of samples are desirable.

Hypothesis/objectives: To test a single sample method of determining GFR in cats.

Animals: The validation population (group 1) consisted of 89 client-owned cats (73 nonazotemic and 16 azotemic). A separate population of 18 healthy nonazotemic cats (group 2) was used to test the methods.

Methods: Glomerular filtration rate was determined in group 1 using corrected slope-intercept iohexol clearance. Single sample clearance was determined using the Jacobsson and modified Jacobsson methods and validated against slope-intercept clearance. Extracellular fluid volume (ECFV) was determined from slope-intercept clearance with correction for the 1 compartment assumption and by deriving a prediction formula for ECFV (ECFV Predicted ) based on the body weight. The optimal single sample method was tested in group 2.

Results: A blood sample at 180 minutes and ECFV Predicted were optimal for single sample clearance. Mean ± SD GFR in group 1 determined using the Jacobsson and modified Jacobsson formulae was 1.78 ± 0.70 and 1.65 ± 0.60 mL/min/kg, respectively. When tested in group 2, the Jacobsson method overestimated multisample clearance. The modified Jacobsson method (mean ± SD 2.22 ± 0.34 mL/min/kg) was in agreement with multisample clearance (mean ± SD 2.19 ± 0.34 mL/min/kg).

Conclusions and clinical importance: The modified Jacobsson method provides accurate estimation of iohexol clearance in cats, from a single sample collected at 180 minutes postinjection and using a formula based on the body weight to predict ECFV. Further validation of the formula in patients with very high or very low GFR is required.

Keywords: Clearance; Function; Iohexol; Renal.

PubMed Disclaimer

LinkOut - more resources