Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2013 Oct;33(10):2543-8.
doi: 10.1007/s00296-013-2769-1. Epub 2013 May 7.

Punctal plugs versus artificial tears for treating primary Sjögren's syndrome with keratoconjunctivitis SICCA: a comparative observation of their effects on visual function

Affiliations
Randomized Controlled Trial

Punctal plugs versus artificial tears for treating primary Sjögren's syndrome with keratoconjunctivitis SICCA: a comparative observation of their effects on visual function

Weiqiang Qiu et al. Rheumatol Int. 2013 Oct.

Abstract

To compare the effects of treatment with punctal plugs versus artificial tears on visual function for primary Sjögren's syndrome with dry eye. Forty-two eyes of 42 patients with primary Sjögren's syndrome were enrolled and were allocated randomly into artificial tears (AT) group and punctal plugs (PP) group. Ocular Surface Disease Index (OSDI) was used, and fluorescent staining for tear film break-up time (BUT), the Schirmer test I (STI) and contrast sensitivity was performed before treatment and was repeated 3 months after treatment. A follow-up of 3 months was achieved in 40 eyes of 40 patients, including 19 eyes in artificial tears group and 21 eyes in punctal plugs group. Statistically significant improvements were observed in the OSDI scores (AT: 52.6 ± 5.7, 15.9 ± 4.2; PP: 55.8 ± 4.9, 15.1 ± 4.2), corneal fluorescein staining scores (AT: 2.60 ± 1.76, 0.30 ± 0.57; PP: 1.91 ± 1.60, 0.09 ± 0.29), STI (AT: 3.85 ± 2.03, 8.95 ± 2.72; PP: 3.36 ± 1.62, 11.41 ± 2.65), and BUT (AT: 2.60 ± 1.39, 6.00 ± 1.81; PP: 2.27 ± 1.12, 7.82 ± 1.84) after treatment compared to those of pre-treatment. The values of STI (AT: 5.10 ± 1.80; PP: 8.05 ± 1.53) and BUT (AT: 3.40 ± 1.31; PP: 5.68 ± 1.13) in punctal plugs group were significantly more improved than those in the artificial tears group. The medium- and high-level frequencies contrast sensitivities were greatly improved in simulated daylight, night, and glare disability conditions after treatment with artificial tears and punctal plugs. However, the changes in contrast sensitivity did not significantly differ between groups. Both artificial tears and punctal plugs relieved dry eye symptoms, repaired corneal lesions, enhanced tear film stability, and improved contrast sensitivity. Punctal plugs could improve tear film stability and elongate the BUT better than artificial tears.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Cornea. 1998 Jul;17(4):376-9 - PubMed
    1. CLAO J. 1989 Jul-Sep;15(3):216-8 - PubMed
    1. Clin Ophthalmol. 2009;3:501-6 - PubMed
    1. Am J Ophthalmol. 2003 May;135(5):704-5 - PubMed
    1. Rheumatol Int. 2011 Dec;31(12):1567-70 - PubMed

Publication types

Substances

LinkOut - more resources