Serial measurements of high-sensitivity cardiac troponin T after exercise stress test in stable coronary artery disease
- PMID: 23651344
- DOI: 10.3109/1354750X.2013.776635
Serial measurements of high-sensitivity cardiac troponin T after exercise stress test in stable coronary artery disease
Abstract
Objective: The aim was to assess serial measurements of high-sensitivity cardiac troponin T (hs-cTNT) post-exercise in patients with stable coronary artery disease (CAD).
Methods: Twelve patients with positive coronary angiograms (CAD positives) and 12 controls performed an exercise stress test.
Results: CAD positive had higher baseline and peak concentrations of hs-cTNT than controls. Significant increases in hs-cTNT were seen in both groups after exercise. In two-third of patients the peak in hs-cTNT was above the 99th percentile.
Conclusion: hs-cTNT is higher in patients with stable coronary disease than in controls and exceeds the diagnostic cut-off value for myocardial infarction in a majority of patients with CAD after exercise.