Flattening filter-free linac improves treatment delivery efficiency in stereotactic body radiation therapy
- PMID: 23652246
- PMCID: PMC5714408
- DOI: 10.1120/jacmp.v14i3.4126
Flattening filter-free linac improves treatment delivery efficiency in stereotactic body radiation therapy
Abstract
Stereotactic body radiation therapy (SBRT) employs precision target tracking and image-guidance techniques to deliver ablative doses of radiation to localized malignancies; however, treatment with conventional photon beams requires lengthy treatment and immobilization times. The use of flattening filter-free (FFF) beams operating at higher dose rates can shorten beam-on time, and we hypothesize that it will shorten overall treatment delivery time. A total of 111 lung and liver SBRT cases treated at our institution from July 2008 to July 2011 were reviewed and 99 cases with complete data were identified. Treatment delivery times for cases treated with a FFF linac versus a conventional dose rate linac were compared. The frequency and type of intrafraction image guidance was also collected and compared between groups. Three hundred and ninety-one individual SBRT fractions from 99 treatment plans were examined; 36 plans were treated with a FFF linac. In the FFF cohort, the mean (± standard deviation) treatment time (time elapsed from beam-on until treatment end) and patient's immobilization time (time from first alignment image until treatment end) was 11.44 (± 6.3) and 21.08 (± 6.8) minutes compared to 32.94 (± 14.8) and 47.05 (± 17.6) minutes for the conventional cohort (p < 0.01 for all values). Intrafraction-computed tomography (CT) was used more often in the conventional cohort (84% vs. 25%; p < 0.05), but use of orthogonal X-ray imaging remained the same (16% vs. 19%). For lung and liver SBRT, a FFF linac reduces treatment and immobilization time by more than 50% compared to a conventional linac. In addition, treatment with a FFF linac is associated with less physician-ordered image guidance, which contributes to further improvement in treatment delivery efficiency.
Figures


Similar articles
-
Stereotactic body radiation therapy (SBRT) for lung malignancies: preliminary toxicity results using a flattening filter-free linear accelerator operating at 2400 monitor units per minute.Radiat Oncol. 2013 Nov 20;8:273. doi: 10.1186/1748-717X-8-273. Radiat Oncol. 2013. PMID: 24256563 Free PMC article.
-
MO-A-BRB-02: Facts and Fiction of Flattening Filter Free (FF-FFF) X-Rays Beams.Med Phys. 2012 Jun;39(6Part20):3861-3862. doi: 10.1118/1.4735765. Med Phys. 2012. PMID: 28517518
-
Investigating the impact of patient arm position in an MR-linac on liver SBRT treatment plans.Med Phys. 2019 Nov;46(11):5144-5151. doi: 10.1002/mp.13826. Epub 2019 Oct 4. Med Phys. 2019. PMID: 31529694
-
Progress and prospects of flattening filter free beam technology in radiosurgery and stereotactic body radiotherapy.Crit Rev Oncol Hematol. 2021 Jul;163:103396. doi: 10.1016/j.critrevonc.2021.103396. Epub 2021 Jun 17. Crit Rev Oncol Hematol. 2021. PMID: 34146680 Review.
-
Emerging technologies in stereotactic body radiotherapy.Chin Clin Oncol. 2017 Sep;6(Suppl 2):S12. doi: 10.21037/cco.2017.06.19. Chin Clin Oncol. 2017. PMID: 28917250 Review.
Cited by
-
Evaluation of a combined respiratory-gating system comprising the TrueBeam linear accelerator and a new real-time tumor-tracking radiotherapy system: a preliminary study.J Appl Clin Med Phys. 2016 Jul 8;17(4):202-213. doi: 10.1120/jacmp.v17i4.6114. J Appl Clin Med Phys. 2016. PMID: 27455483 Free PMC article.
-
Ex Vivo Irradiation of Lung Cancer Stem Cells Identifies the Lowest Therapeutic Dose Needed for Tumor Growth Arrest and Mass Reduction In Vivo.Front Oncol. 2022 May 12;12:837400. doi: 10.3389/fonc.2022.837400. eCollection 2022. Front Oncol. 2022. PMID: 35646627 Free PMC article.
-
Dosimetric differences in flattened and flattening filter-free beam treatment plans.J Med Phys. 2016 Apr-Jun;41(2):92-9. doi: 10.4103/0971-6203.181636. J Med Phys. 2016. PMID: 27217620 Free PMC article.
-
Radiobiological effects of flattening filter-free photon beams on A549 non-small-cell lung cancer cells.J Radiat Res. 2018 Jul 1;59(4):442-445. doi: 10.1093/jrr/rry041. J Radiat Res. 2018. PMID: 29850845 Free PMC article.
-
Flattening filter-free technique in volumetric modulated arc therapy for lung stereotactic body radiotherapy: A clinical comparison with the flattening filter technique.Oncol Lett. 2018 Mar;15(3):3928-3936. doi: 10.3892/ol.2018.7809. Epub 2018 Jan 16. Oncol Lett. 2018. PMID: 29563993 Free PMC article.
References
-
- Rusthoven KE, Kavanagh BD, Burri SH, et al. Multi‐institutional phase I/II trial of stereotactic body radiation therapy for lung metastases. J Clin Oncol. 2009;27(10):1579–84. - PubMed
-
- Rusthoven KE, Kavanagh BD, Cardenes H, et al. Multi‐institutional phase I/II trial of stereotactic body radiation therapy for liver metastases. J Clin Oncol. 2009;27(10):1572–78. - PubMed
-
- Timmerman RD, Park C, Kavanagh BD. The North American experience with stereotactic body radiation therapy in non‐small cell lung cancer. J Thorac Oncol. 2007;2(7 Suppl 3):S101–S112. - PubMed
-
- Timmerman R, McGarry R, Yiannoutsos C, et al. Excessive toxicity when treating central tumors in a phase II study of stereotactic body radiation therapy for medically inoperable early‐stage lung cancer. J Clin Oncol. 2006;24(30):4833–39. - PubMed
-
- Nagata Y, Takayama K, Matsuo Y, et al. Clinical outcomes of a phase I/II study of 48 Gy of stereotactic body radiotherapy in 4 fractions for primary lung cancer using a stereotactic body frame. Int J Radiat Oncol Biol Phys. 2005;63(5):1427–31. - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical