Surface-length index: a novel index for rapid detection of right ventricles with abnormal ejection fraction using cardiac MRI
- PMID: 23657287
- DOI: 10.1007/s00330-013-2851-9
Surface-length index: a novel index for rapid detection of right ventricles with abnormal ejection fraction using cardiac MRI
Abstract
Objective: To validate a new index, the surface-length index (SLI) based on area change in a short-axis view and length reduction in the horizontal long-axis view, which is used to quickly (<1 min) detect right ventricles with an abnormal ejection fraction (EF) during a cardiac MRI examination. SLI can be used to avoid a complete delineation of the endocardial contours of normal right ventricles.
Methods: Sixty patients (group A) were retrospectively included to calibrate the SLI formula by optimisation of the area under the ROC curves and SLI thresholds were chosen to obtain 100 % sensitivity. Another 340 patients (group B) were prospectively recruited to test SLI's capacity to detect right ventricles (RVs) with an abnormal EF (<0.5).
Results: The appropriate threshold to obtain 100 % sensitivity in group A was 0.58. In group B, with the 0.58 threshold, SLI yielded a sensitivity of 100 % and specificity of 51 %. SLI would have saved 35 % of the RV studies in our population, without inducing any diagnostic error. SLI and EF correlation was good (r (2) = 0.64).
Conclusion: SLI combines two simple RV measures, and brings significant improvement in post-processing efficiency by preselecting RVs that require a complete study.
Key points: • Assessment of right ventricle ejection fraction (RVEF) with cine-MRI is time consuming. • Therefore, RVEF is not always assessed during cardiac MRI. • Surface-length index (SLI) allows rapid detection of abnormal RVEF during cardiac MRI. • SLI saves one third of the operator time. • Every cardiac MRI could include RVEF assessment by means of SLI.
Similar articles
-
Accuracy of a new method for semi-quantitative assessment of right ventricular ejection fraction by cardiovascular magnetic resonance: right ventricular fractional diameter changes.Eur J Radiol. 2014 Jan;83(1):130-4. doi: 10.1016/j.ejrad.2013.10.004. Epub 2013 Oct 17. Eur J Radiol. 2014. PMID: 24252456
-
Tissue Doppler study of the right ventricle with a multisegmental approach: comparison with cardiac magnetic resonance imaging.J Am Soc Echocardiogr. 2009 Apr;22(4):361-8. doi: 10.1016/j.echo.2009.01.018. J Am Soc Echocardiogr. 2009. PMID: 19345305
-
Right ventricular global longitudinal strain is an independent predictor of right ventricular function: a multimodality study of cardiac magnetic resonance imaging, real time three-dimensional echocardiography and speckle tracking echocardiography.Echocardiography. 2015 Jun;32(6):966-74. doi: 10.1111/echo.12783. Epub 2014 Oct 7. Echocardiography. 2015. PMID: 25287078
-
Traditional and innovative echocardiographic parameters for the analysis of right ventricular performance in comparison with cardiac magnetic resonance.Eur Heart J Cardiovasc Imaging. 2015 Jan;16(1):47-52. doi: 10.1093/ehjci/jeu156. Epub 2014 Sep 3. Eur Heart J Cardiovasc Imaging. 2015. PMID: 25187607
-
Tricuspid annular plane systolic excursion is dependent on right ventricular volume in addition to function.Echocardiography. 2019 Aug;36(8):1459-1466. doi: 10.1111/echo.14439. Epub 2019 Aug 7. Echocardiography. 2019. PMID: 31389082
Cited by
-
Fast assessment of long axis strain with standard cardiovascular magnetic resonance: a validation study of a novel parameter with reference values.J Cardiovasc Magn Reson. 2015 Aug 8;17(1):69. doi: 10.1186/s12968-015-0171-8. J Cardiovasc Magn Reson. 2015. PMID: 26253220 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources