The additional value of live/real-time three-dimensional transesophageal echocardiography over two-dimensional transesophageal echocardiography for assessing mitral regurgitation with eccentric jets
- PMID: 23664737
- DOI: 10.1016/j.jcma.2013.04.001
The additional value of live/real-time three-dimensional transesophageal echocardiography over two-dimensional transesophageal echocardiography for assessing mitral regurgitation with eccentric jets
Abstract
Background: Two-dimensional transesophageal echocardiography (2D TEE) Doppler color flow imaging is the gold standard for assessing the severity of mitral regurgitation (MR). Severe MR with very eccentric jet may involve more than one mitral leaflet lesion and can be missed by 2D TEE. The purpose of this study was to assess the usefulness and the incremental value of real-time three-dimensional (RT 3D) TEE over 2D TEE findings in the evaluation of patients suffering eccentric MR with more than one mitral leaflet lesion.
Methods: Intraoperative 2D TEE and RT 3D TEE examinations were performed on 168 patients with Carpenter II MR who underwent surgery. MR was defined as either central, free-standing eccentric jet or very eccentric jet. 2D TEE and RT 3D TEE finding were compared with surgical findings.
Results: Of these 168 MR patients, 25 patients (14.9%) had central jets and 143 patients (85.1%) had eccentric jets. Among 143 patients with eccentric jets, 47 patients (32.9%) had free-standing eccentric MR jets, and 96 (67.1%) patients had very eccentric jets. 3D TEE diagnosed the severity and location of MR lesions correctly in all patients; this was not the case with 2D TEE, which had significant diagnostic misses in nine patients (9.4%, p < 0.001) having MR with very eccentric jets. These nine patients had lesions on both mitral leaflets, which were missed during 2D TEE examination owing to the highly turbulent flows produced by very eccentric jets from one mitral leaflet lesion and impinging the opposite mitral leaflet lesion.
Conclusion: The severity of MR with very eccentric jet was more accurately and comprehensively assessed by 3D TEE than by 2D TEE. Therefore, intraoperative RT 3D TEE provides incremental information that is generally superior to 2D TEE in patients with complex MR due to very eccentric jets.
Copyright © 2013. Published by Elsevier B.V.
Similar articles
-
Comparative accuracy of two- and three-dimensional transthoracic and transesophageal echocardiography in identifying mitral valve pathology in patients undergoing mitral valve repair: initial observations.J Am Soc Echocardiogr. 2011 Oct;24(10):1079-85. doi: 10.1016/j.echo.2011.06.011. Epub 2011 Jul 30. J Am Soc Echocardiogr. 2011. PMID: 21803543
-
Understanding Non-P2 Mitral Regurgitation Using Real-Time Three-Dimensional Transesophageal Echocardiography: Characterization and Factors Leading to Underestimation.J Am Soc Echocardiogr. 2020 Jul;33(7):826-837. doi: 10.1016/j.echo.2020.03.011. Epub 2020 May 6. J Am Soc Echocardiogr. 2020. PMID: 32387034
-
Direct measurement of multiple vena contracta areas for assessing the severity of mitral regurgitation using 3D TEE.JACC Cardiovasc Imaging. 2012 Jul;5(7):669-76. doi: 10.1016/j.jcmg.2012.03.008. JACC Cardiovasc Imaging. 2012. PMID: 22789934
-
3D transesophageal echocardiography: A new imaging tool for assessment of mitral regurgitation and for guiding percutaneous edge-to-edge mitral valve repair.Prog Cardiovasc Dis. 2017 Nov-Dec;60(3):305-321. doi: 10.1016/j.pcad.2017.10.001. Epub 2017 Oct 19. Prog Cardiovasc Dis. 2017. PMID: 29056395 Review.
-
[The emerging role of three-dimensional transesophageal echocardiography in guiding the MitraClip procedure].G Ital Cardiol (Rome). 2015 Oct;16(10):549-54. doi: 10.1714/2028.22038. G Ital Cardiol (Rome). 2015. PMID: 26444213 Review. Italian.
Cited by
-
Evaluation of left ventricular function in patients with heart failure after myocardial infarction by real-time three-dimensional transesophageal echocardiography.Am J Transl Res. 2021 Sep 15;13(9):10380-10387. eCollection 2021. Am J Transl Res. 2021. PMID: 34650706 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources