Advanced three-dimensional quantitative coronary angiographic assessment of bifurcation lesions: methodology and phantom validation
- PMID: 23680960
- DOI: 10.4244/EIJV8I12A219
Advanced three-dimensional quantitative coronary angiographic assessment of bifurcation lesions: methodology and phantom validation
Abstract
Aims: Validation of new three-dimensional (3-D) bifurcation quantitative coronary angiography (QCA) software.
Methods and results: Cardiovascular Angiography Analysis System (CAAS 5v10) allows 3-D angiographic reconstructions based on two or more 2-D projection images. Measurements for minimal lumen diameter (MLD), reference vessel diameter (RVD), percent diameter stenosis (DS) and bifurcation angle (BA) were validated against precision manufactured phantom bifurcations. Length measurements were validated against angiographic measurement catheters inserted into a plexiglas bifurcation phantom. In 3-D reconstructions based on two 2-D images, acquired at variable rotation and angulation, accuracy and precision (mean difference ± SD) of the 11-segment model for MLD, RVD and DS were 0.013±0.131 mm, -0.052±0.039 mm and -1.08±5.13%, respectively; inter-observer variability was 0.141 mm, 0.058 mm and 5.42%, respectively. Adding the antero-posterior (optimal) projection to these basic reconstructions resulted in reduced variability (0.101 mm, 0.041 mm and 3.93% for MLD, RVD and DS, p<0.01 for all) and showed a trend towards improved precision (0.109 mm, 0.031 mm and 4.26%, respectively, p>0.05 for all). In basic reconstructions, accuracy and precision for BA was -1.3±5.0°, whereas inter-observer variability was 7.5°; respective measures for length were 0.15±0.26 mm and 0.54 mm. Adding the antero-posterior projection resulted in decreased precision (0.47 mm, p<0.01) and increased variability (1.03 mm, p<0.01) for length measurements; precision (5.4°) and variability (7.9°) for BA did not change significantly (p>0.30).
Conclusions: Advances in the methodology of 3-D reconstruction and quantitative analysis for bifurcation lesions translated into highly accurate, precise and reproducible measures of diameter, length and BA.
Similar articles
-
Two-dimensional quantitative coronary angiographic models for bifurcation segmental analysis: in vitro validation of CAAS against precision manufactured plexiglas phantoms.Catheter Cardiovasc Interv. 2011 May 1;77(6):830-9. doi: 10.1002/ccd.22844. Epub 2011 Mar 16. Catheter Cardiovasc Interv. 2011. PMID: 20939040
-
Advances in two-dimensional quantitative coronary angiographic assessment of bifurcation lesions: improved small lumen diameter detection and automatic reference vessel diameter derivation.EuroIntervention. 2012 Mar;7(11):1326-35. doi: 10.4244/EIJV7I11A208. EuroIntervention. 2012. PMID: 22433196
-
Novel bifurcation phantoms for validation of quantitative coronary angiography algorithms.Catheter Cardiovasc Interv. 2011 May 1;77(6):790-7. doi: 10.1002/ccd.22704. Catheter Cardiovasc Interv. 2011. PMID: 20602479
-
The need for dedicated bifurcation quantitative coronary angiography (QCA) software algorithms to evaluate bifurcation lesions.EuroIntervention. 2015;11 Suppl V:V44-9. doi: 10.4244/EIJV11SVA10. EuroIntervention. 2015. PMID: 25983170 Review.
-
Three-Dimensional Angle Assessment and Plaque Distribution Classification in Left Main Disease: Impact of Geometry on Outcome.Rev Cardiovasc Med. 2015;16(2):131-9. doi: 10.3909/ricm0763. Rev Cardiovasc Med. 2015. PMID: 26198560 Review.
Cited by
-
Automatic evaluation of vessel diameter variation from 2D X-ray angiography.Int J Comput Assist Radiol Surg. 2017 Nov;12(11):1867-1876. doi: 10.1007/s11548-017-1639-9. Epub 2017 Jul 13. Int J Comput Assist Radiol Surg. 2017. PMID: 28707212
-
Definitions and standardized endpoints for the use of drug-coated balloon in coronary artery disease: consensus document of the Drug Coated Balloon Academic Research Consortium.Eur Heart J. 2025 Jul 7;46(26):2498-2519. doi: 10.1093/eurheartj/ehaf029. Eur Heart J. 2025. PMID: 40270117 Free PMC article.
-
Effective descriptor extraction strategies for correspondence matching in coronary angiography images.Sci Rep. 2024 Aug 11;14(1):18630. doi: 10.1038/s41598-024-69153-5. Sci Rep. 2024. PMID: 39128936 Free PMC article.
-
Impact of coronary bifurcation angle on the pathogenesis of atherosclerosis and clinical outcome of coronary bifurcation intervention-A scoping review.PLoS One. 2022 Aug 17;17(8):e0273157. doi: 10.1371/journal.pone.0273157. eCollection 2022. PLoS One. 2022. PMID: 35976920 Free PMC article.
-
Fusion of fibrous cap thickness and wall shear stress to assess plaque vulnerability in coronary arteries: a pilot study.Int J Comput Assist Radiol Surg. 2016 Oct;11(10):1779-90. doi: 10.1007/s11548-016-1422-3. Epub 2016 May 28. Int J Comput Assist Radiol Surg. 2016. PMID: 27236652 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical