The effect of portable pulsed xenon ultraviolet light after terminal cleaning on hospital-associated Clostridium difficile infection in a community hospital
- PMID: 23685092
- DOI: 10.1016/j.ajic.2013.02.010
The effect of portable pulsed xenon ultraviolet light after terminal cleaning on hospital-associated Clostridium difficile infection in a community hospital
Abstract
There is evidence that contamination of patient rooms from previous occupants is associated with hospital-associated Clostridium difficile infection (HA-CDI). During January 2011, the use of 2 portable pulsed xenon ultraviolet light devices (PPX-UV) to disinfect patient rooms was added to routine hospital discharge cleaning in a community hospital. In 2010, the HA-CDI rate was 9.46 per 10,000 patient-days; in 2011, the HA-CDI rates was 4.45 per 10,000 patient-days (53% reduction, P = .01). The number of deaths and colectomies attributable to hospital-associated C difficile infection also declined dramatically.
Keywords: C difficile; Colectomy; Disinfection; Hospital infection; Technology; UV light.
Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Similar articles
-
A trial of pulsed xenon ultraviolet disinfection to reduce Clostridioides difficile infection.Am J Infect Control. 2019 Apr;47(4):406-408. doi: 10.1016/j.ajic.2018.09.018. Epub 2018 Nov 28. Am J Infect Control. 2019. PMID: 30502111
-
Clostridium difficile infections before and during use of ultraviolet disinfection.Am J Infect Control. 2015 Sep 1;43(9):940-5. doi: 10.1016/j.ajic.2015.05.003. Epub 2015 Jul 6. Am J Infect Control. 2015. PMID: 26159499
-
Proposed checklist of hospital interventions to decrease the incidence of healthcare-associated Clostridium difficile infection.Infect Control Hosp Epidemiol. 2009 Nov;30(11):1062-9. doi: 10.1086/644757. Infect Control Hosp Epidemiol. 2009. PMID: 19751156
-
How to eradicate Clostridium difficile from the environment.J Hosp Infect. 2015 Apr;89(4):287-95. doi: 10.1016/j.jhin.2014.12.007. Epub 2015 Jan 7. J Hosp Infect. 2015. PMID: 25638358 Review.
-
Portable Ultraviolet Light Surface-Disinfecting Devices for Prevention of Hospital-Acquired Infections: A Health Technology Assessment.Ont Health Technol Assess Ser. 2018 Feb 7;18(1):1-73. eCollection 2018. Ont Health Technol Assess Ser. 2018. PMID: 29487629 Free PMC article. Review.
Cited by
-
Controlling hospital-acquired infection: focus on the role of the environment and new technologies for decontamination.Clin Microbiol Rev. 2014 Oct;27(4):665-90. doi: 10.1128/CMR.00020-14. Clin Microbiol Rev. 2014. PMID: 25278571 Free PMC article. Review.
-
Potential of pulsed light technology for control of SARS-CoV-2 in hospital environments.J Photochem Photobiol B. 2021 Feb;215:112106. doi: 10.1016/j.jphotobiol.2020.112106. Epub 2020 Dec 28. J Photochem Photobiol B. 2021. PMID: 33383557 Free PMC article. Review.
-
Performance of an Autonomous Sanitary Sterilisation Ultraviolet Machine (ASSUM) on terminal disinfection of surgical theaters and rooms of an intensive-intermediate care unit.Infect Prev Pract. 2024 Aug 29;6(4):100396. doi: 10.1016/j.infpip.2024.100396. eCollection 2024 Dec. Infect Prev Pract. 2024. PMID: 39308772 Free PMC article.
-
Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals.Antimicrob Resist Infect Control. 2016 Apr 11;5:10. doi: 10.1186/s13756-016-0111-x. eCollection 2016. Antimicrob Resist Infect Control. 2016. PMID: 27069623 Free PMC article. Review.
-
Development of a Pulsed Xenon Ultraviolet Disinfection Device for Real-Time Air Disinfection in Ambulances.J Healthc Eng. 2020 Feb 24;2020:6053065. doi: 10.1155/2020/6053065. eCollection 2020. J Healthc Eng. 2020. PMID: 32184979 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical