Differences between office and 24-hour blood pressure control in hypertensive patients with CKD: A 5,693-patient cross-sectional analysis from Spain
- PMID: 23689071
- DOI: 10.1053/j.ajkd.2013.03.025
Differences between office and 24-hour blood pressure control in hypertensive patients with CKD: A 5,693-patient cross-sectional analysis from Spain
Erratum in
- Am J Kidney Dis. 2013 Dec;62(6):1230
Abstract
Background: Previous studies have examined control rates of office blood pressure (BP) in chronic kidney disease (CKD). However, recent evidence suggests major discrepancies between office and 24-hour BP values in hypertensive populations. This study examined concordance/discordance between office- and ambulatory-based BP control in a large cohort of patients with CKD.
Study design: Cross-sectional.
Setting & participants: 5,693 hypertensive individuals with CKD stages 1-5 from the Spanish ABPM (ambulatory BP monitoring) Registry.
Predictors: Thresholds of 140/90 and 130/80 mm Hg for office BP and 24-hour ambulatory BP, respectively. Age, sex, body mass index, waist circumference, hypertension duration, kidney measures, diabetes, dyslipidemia, target-organ damage, and cardiovascular comorbid conditions.
Outcomes: Misclassification of BP control as "white-coat" hypertension (office BP ≥140/90 mm Hg, 24-hour BP <130/80 mm Hg) or masked hypertension (office BP <140/90 mm Hg, 24-hour BP ≥130/80 mm Hg).
Measurements: Standardized office-based BP and 24-hour ABPM.
Results: Mean age was 61.0 ± 13.9 (SD) years and 52.6% were men. The proportion with white-coat hypertension was 28.8% (36.8% of patients with office BP ≥140/90 mm Hg) and that of masked hypertension was 7.0% (but 32.1% of patients with office BP <140/90 mm Hg). Female sex, aging, obesity, and target-organ damage were associated with white-coat hypertension; aging and obesity were associated with masked hypertension. Only 21.7% and 8.1% of the CKD population had office BP <140/90 and <130/80 mm Hg, respectively. In contrast, 43.5% of individuals had average 24-hour BP <130/80 mm Hg.
Limitations: Cross-sectional design, longitudinal associations cannot be established.
Conclusions: Misclassification of BP control at the office was observed in 1 of 3 hypertensive patients with CKD. Ambulatory-based control rates were far better than office-based rates. Nevertheless, the burden of uncontrolled ambulatory BP and misclassification of BP control at the office constitutes a call for wider use of ABPM to evaluate the success of hypertension treatment in patients with CKD.
Keywords: Chronic kidney disease; ambulatory; control; hypertension; treatment.
Copyright © 2013 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous
