Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2013 May 21;127(20):2021-30.
doi: 10.1161/CIRCULATIONAHA.112.000447.

Safety of sports for athletes with implantable cardioverter-defibrillators: results of a prospective, multinational registry

Affiliations
Multicenter Study

Safety of sports for athletes with implantable cardioverter-defibrillators: results of a prospective, multinational registry

Rachel Lampert et al. Circulation. .

Abstract

Background: The risks of sports participation for implantable cardioverter-defibrillator (ICD) patients are unknown.

Methods and results: Athletes with ICDs (age, 10-60 years) participating in organized (n=328) or high-risk (n=44) sports were recruited. Sports-related and clinical data were obtained by phone interview and medical records. Follow-up occurred every 6 months. ICD shock data and clinical outcomes were adjudicated by 2 electrophysiologists. Median age was 33 years (89 subjects <20 years of age); 33% were female. Sixty were competitive athletes (varsity/junior varsity/traveling team). A pre-ICD history of ventricular arrhythmia was present in 42%. Running, basketball, and soccer were the most common sports. Over a median 31-month (interquartile range, 21-46 months) follow-up, there were no occurrences of either primary end point-death or resuscitated arrest or arrhythmia- or shock-related injury-during sports. There were 49 shocks in 37 participants (10% of study population) during competition/practice, 39 shocks in 29 participants (8%) during other physical activity, and 33 shocks in 24 participants (6%) at rest. In 8 ventricular arrhythmia episodes (device defined), multiple shocks were received: 1 at rest, 4 during competition/practice, and 3 during other physical activity. Ultimately, the ICD terminated all episodes. Freedom from lead malfunction was 97% at 5 years (from implantation) and 90% at 10 years.

Conclusions: Many athletes with ICDs can engage in vigorous and competitive sports without physical injury or failure to terminate the arrhythmia despite the occurrence of both inappropriate and appropriate shocks. These data provide a basis for more informed physician and patient decision making in terms of sports participation for athletes with ICDs.

Keywords: defibrillators, implantable; sports.

PubMed Disclaimer

Publication types

LinkOut - more resources