Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comment
. 2013 Jun 14;17(3):155.
doi: 10.1186/cc12599.

Measuring and reporting glycemic control in clinical trials: building a path to consensus

Comment

Measuring and reporting glycemic control in clinical trials: building a path to consensus

Carmen L Soto-Rivera et al. Crit Care. .

Abstract

Clinical trials over time have used a variety of approaches for both measuring tight glycemic control and reporting results. The review by Finfer and colleagues in this issue of Critical Care is a step toward consensus within the research community to standardize the way blood glucose is measured and reported in clinical trials. The authors propose using specific measures of central tendency and dispersion for reporting glucose, advocate the use of blood gas analyzers and elimination of point-of-care glucose monitors in the intensive care unit, and comment on performance of continuous glucose monitors. As we await the release of updated rules from the International Standards Organization and process the new rules from the Clinical Laboratory and Standards Institute to regulate glucose monitoring, these recommendations should trigger many more conversations within the field as we strive for uniformity. However, we need to be cautious in prematurely proposing and adopting standards of care that fail to account for newer technology and data in this rapidly growing area of research.

PubMed Disclaimer

Comment on

References

    1. Finfer S, Wernerman J, Preiser JC, Cass T, Desaive T, Hovorka R, Joseph JI, Kosiborod M, Krinsley J, Mackenzie I, Mesotten D, Schultz MJ, Scott MG, Slingerland R, Van den Berghe G, Van Herpe T. Clinical review: Consensus recommendations on 'Measurement of blood glucose and reporting glycemic control in critically ill adults'. Crit Care. 2013;17:229. doi: 10.1186/cc12537. - DOI - PMC - PubMed
    1. Gijzen K, Moolenaar DL, Weusten JJ, Pluim HJ, Demir AY. Is there a suitable point-of-care glucose meter for tight glycemic control? Evaluation of one home-use and four hospital-use meters in an intensive care unit. Clin Chem Lab Med. 2012;50:1985–1992. - PubMed
    1. ISO 15197:2003. In vitro diagnostic test systems--requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus. 2009.
    1. Heinemann L, Lodwig V, Freckmann G. Accuracy in blood glucose measurement: what will a tightening of requirements yield? J Diabetes Sci Technol. 2012;6:435–443. - PMC - PubMed
    1. ISO/FDIS 15197. In vitro diagnostic test systems--requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus. Under development, stage 50.20.

MeSH terms