Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Jun 21;54(6):4235-40.
doi: 10.1167/iovs.13-12357.

MRI acquisition and analysis protocol for in vivo intraorbital optic nerve segmentation at 3T

Affiliations

MRI acquisition and analysis protocol for in vivo intraorbital optic nerve segmentation at 3T

Marios C Yiannakas et al. Invest Ophthalmol Vis Sci. .

Abstract

Purpose: To present a new acquisition and analysis protocol for reliable and reproducible segmentation of the entire intraorbital optic nerve (ION) mean cross-sectional area by means of magnetic resonance imaging (MRI) at 3 tesla (T).

Methods: Eight healthy volunteers (mean age 31, five were male) gave written informed consent and both of their IONs were imaged individually using a coronal-oblique T2-weighted fast multidynamic image acquisition scheme; the proposed acquisition scheme has its rationale in combining separately acquired volumes and registering them to account for motion-related artifacts commonly associated with longer acquisitions. Mean cross-sectional area of each ION was measured using a semiautomated image analysis protocol that was based on an active surface model previously described and used for spinal cord imaging. Reproducibility was assessed for repeated scans (scan-rescan) and repeated image analysis performance (intraobserver).

Results: Mean and SD values of the left ION cross-sectional area for the eight healthy volunteers were 5.0 (±0.7) mm² and for the right ION were 5.3 (±0.8) mm². Mean scan-rescan coefficient of variation (COV) for the left ION was 4.3% and for the right was 4.4%. Mean intraobserver COV for the left ION was 2.1% and for the right was 1.8%.

Conclusions: This study presents a new MRI acquisition and analysis protocol for reliable and reproducible in vivo measurement of the entire ION mean cross-sectional area as demonstrated in a pilot study of healthy subjects. The protocol presented here can be used in future studies of the ION in disease state.

Keywords: MRI; optic nerve; segmentation.

PubMed Disclaimer

Publication types

LinkOut - more resources