Circulatory death determination in uncontrolled organ donors: a panel viewpoint
- PMID: 23796628
- DOI: 10.1016/j.annemergmed.2013.05.018
Circulatory death determination in uncontrolled organ donors: a panel viewpoint
Abstract
One barrier for implementing programs of uncontrolled organ donation after the circulatory determination of death is the lack of consensus on the precise moment of death. Our panel was convened to study this question after we performed a similar analysis on the moment of death in controlled organ donation after the circulatory determination of death. We concluded that death could be determined by showing the permanent or irreversible cessation of circulation and respiration. Circulatory irreversibility may be presumed when optimal cardiopulmonary resuscitation efforts have failed to restore circulation and at least a 7-minute period has elapsed thereafter during which autoresuscitation to restored circulation could occur. We advise against the use of postmortem organ support technologies that reestablish circulation of warm oxygenated blood because of their risk of retroactively invalidating the required conditions on which death was declared.
Copyright © 2013. Published by Mosby, Inc.
Comment in
-
Donation after circulatory determination of death: time for transparency.Ann Emerg Med. 2014 Apr;63(4):401-3. doi: 10.1016/j.annemergmed.2013.09.020. Epub 2013 Nov 7. Ann Emerg Med. 2014. PMID: 24210366 No abstract available.