Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Oct;32(10):1910-27.
doi: 10.1109/TMI.2013.2269139. Epub 2013 Jun 19.

Dynamic contrast-enhanced MRI-based early detection of acute renal transplant rejection

Dynamic contrast-enhanced MRI-based early detection of acute renal transplant rejection

Fahmi Khalifa et al. IEEE Trans Med Imaging. 2013 Oct.

Abstract

A novel framework for the classification of acute rejection versus nonrejection status of renal transplants from 2-D dynamic contrast-enhanced magnetic resonance imaging is proposed. The framework consists of four steps. First, kidney objects are segmented from adjacent structures with a level set deformable boundary guided by a stochastic speed function that accounts for a fourth-order Markov-Gibbs random field model of the kidney/background shape and appearance. Second, a Laplace-based nonrigid registration approach is used to account for local deformations caused by physiological effects. Namely, the target kidney object is deformed over closed, equispaced contours (iso-contours) to closely match the reference object. Next, the cortex is segmented as it is the functional kidney unit that is most affected by rejection. To characterize rejection, perfusion is estimated from contrast agent kinetics using empirical indexes, namely, the transient phase indexes (peak signal intensity, time-to-peak, and initial up-slope), and a steady-phase index defined as the average signal change during the slowly varying tissue phase of agent transit. We used a kn-nearest neighbor classifier to distinguish between acute rejection and nonrejection. Performance of our method was evaluated using the receiver operating characteristics (ROC). Experimental results in 50 subjects, using a combinatoric kn-classifier, correctly classified 92% of training subjects, 100% of the test subjects, and yielded an area under the ROC curve that approached the ideal value. Our proposed framework thus holds promise as a reliable noninvasive diagnostic tool.

PubMed Disclaimer