Replacing manual sphygmomanometers with automated blood pressure measurement in routine clinical practice
- PMID: 23819734
- DOI: 10.1111/1440-1681.12149
Replacing manual sphygmomanometers with automated blood pressure measurement in routine clinical practice
Abstract
1. Conventional manual measurement of blood pressure (BP) in clinical practice is no longer considered to be the best method for evaluating a patient's BP status. Home BP and 24 h ambulatory BP monitoring are now recommended for the diagnosis and management of hypertension. 2. Recent studies provide an alternative to conventional office BP, namely automated office (AO) BP, which involves multiple BP readings taken with a fully automated device with the patient resting quietly alone. Automated office BP is preferable to routine manual office BP in that it exhibits improved accuracy and a stronger relationship to both ambulatory BP and target organ damage. 3. Having the patient alone eliminates conversation between the patient and the observer, a cause of 'white coat hypertension'. The use of an automated device improves accuracy, reduces digit preference, minimizes observer bias and facilitates the recording of multiple BP readings. 4. Comparative BP data obtained in clinical studies in both research settings and routine community practice support the use of a cut-off point of 135/85 mmHg for defining hypertension using AOBP, which is the same cut-off point currently recommended for awake ambulatory BP and home BP. 5. Reduction of the white coat response using AOBP should reduce the need to monitor patients with ambulatory BP and home BP after initiation of antihypertensive therapy. There is now sufficient evidence to consider replacing manual office BP with AOBP in routine clinical practice.
Keywords: automated blood pressure measurement; hypertension diagnosis; white coat hypertension.
© 2013 Wiley Publishing Asia Pty Ltd.
Similar articles
-
Automated office blood pressure.Can J Cardiol. 2012 May;28(3):341-6. doi: 10.1016/j.cjca.2011.09.004. Epub 2012 Jan 20. Can J Cardiol. 2012. PMID: 22265230 Review.
-
The great myth of office blood pressure measurement.J Hypertens. 2012 Oct;30(10):1894-8. doi: 10.1097/HJH.0b013e3283577b05. J Hypertens. 2012. PMID: 22871894 Review.
-
Office blood pressure measurement in the 21st century.J Clin Hypertens (Greenwich). 2018 Jul;20(7):1104-1107. doi: 10.1111/jch.13276. J Clin Hypertens (Greenwich). 2018. PMID: 30003698 Free PMC article.
-
Why use automated office blood pressure measurements in clinical practice?High Blood Press Cardiovasc Prev. 2011 Sep 1;18(3):89-91. doi: 10.2165/11593510-000000000-00000. High Blood Press Cardiovasc Prev. 2011. PMID: 21950780
-
Automated office blood pressure measurement in primary care.Can Fam Physician. 2014 Feb;60(2):127-32. Can Fam Physician. 2014. PMID: 24522674 Free PMC article. Review.
Cited by
-
Comparison of minute distribution frequency for anesthesia start and end times from an anesthesia information management system and paper records.J Clin Monit Comput. 2017 Aug;31(4):845-850. doi: 10.1007/s10877-016-9893-x. Epub 2016 Jun 7. J Clin Monit Comput. 2017. PMID: 27270785
-
Association of Deepwater Horizon Oil Spill Response and Cleanup Work With Risk of Developing Hypertension.JAMA Netw Open. 2022 Feb 1;5(2):e220108. doi: 10.1001/jamanetworkopen.2022.0108. JAMA Netw Open. 2022. PMID: 35195699 Free PMC article.
-
Blood Pressure Measurement Modalities: A Primer for Busy Practitioners.J Clin Hypertens (Greenwich). 2016 Apr;18(4):262-6. doi: 10.1111/jch.12709. Epub 2015 Nov 12. J Clin Hypertens (Greenwich). 2016. PMID: 26558475 Free PMC article. No abstract available.
-
Measurement of Blood Pressure by Ultrasound-The Applicability of Devices, Algorithms and a View in Local Hemodynamics.Diagnostics (Basel). 2021 Dec 2;11(12):2255. doi: 10.3390/diagnostics11122255. Diagnostics (Basel). 2021. PMID: 34943492 Free PMC article.
-
Clinical value of ambulatory blood pressure in pediatric patients after renal transplantation.Pediatr Nephrol. 2018 Aug;33(8):1327-1336. doi: 10.1007/s00467-017-3781-6. Epub 2017 Aug 25. Pediatr Nephrol. 2018. PMID: 28842790 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical