[Application of a sponaneous ventilation protocol. Experiences from a weaning center for neurological diseases]
- PMID: 23821290
- DOI: 10.1007/s00115-013-3812-x
[Application of a sponaneous ventilation protocol. Experiences from a weaning center for neurological diseases]
Abstract
Objective: The aim of this study was to investigate a novel standardized protocol in this neurological weaning unit in order to optimize the weaning process for patients subjected to prolonged mechanical ventilation. Of primary interest were the frequency of and reasons for deviating from the protocol as well as risk factors for weaning failure and mortality.
Patients and methods: All patients admitted to the weaning unit were enrolled in this prospective observational study. The weaning protocol consisted of 22 discrete weaning steps. An individual weaning approach was only begun if the standardized protocol failed. Variables for risk analysis included age, body mass index, APACHE II score, reason for initiating mechanical ventilation, total duration of inpatient stay before admission to the weaning unit, extent of mechanical ventilation period before admission, chronic pulmonary diseases and dialysis.
Results: Between October 2007 and December 2008 a total of 644 consecutively admitted patients were enrolled in the study. The mean age was 67.6 ± 12.3 years, the mean inpatient stay before admission was 45.8 ± 34.9 days and the mean duration of mechanical ventilation before admission to the unit was 38.1 ± 28.7 days. The mean APACHE II score was 19.0 ± 7.2, 68 % of the patients were male, 98.6 % had a tracheotomy tube, 30.9 % had a history of chronic pulmonary disease and 13.7 % required dialysis. Reasons for initiating ventilation were cerebral 33.1 %, pulmonary 28.7 %, cardiovascular 31.5 %, neuropathic 2.8 %, myopathic 0.9 %, spinal cord injuries 1.9 % and 1.1 % were unclear. Weaning was successful in 77.3 % (498 patients) of all cases with a mean duration of 22.0 ± 33.9 days. Of those successfully weaned, a total of 85.9 % (n = 428) were weaned according to the standard protocol. The weaning process was also shorter (20.8 ± 35.6 versus 29.0 ± 19.9 days) for those patients weaned according to the protocol compared to those patients where the protocol failed. Protocol failure was normally due to complications during the weaning process. Among the patients where the protocol failed, chronic pulmonary disease (41.4 versus 28.3 %; p < 0.02), a longer duration of ventilation (42.3 ± 22.8 versus 35.9 ± 25.3 days; p < 0.01) and a longer in-hospital stay (52.7 ± 41.4 versus 42.4 ± 30.1 days; p < 0.01) prior to admission were significantly more common. A total of 23.0 % (n = 148) of the patients died and 9.8 % (n = 63) of the patients were discharged into a home care ventilation program. Chronic pulmonary disease and the duration of inpatient stay prior to admission were predictors of weaning failure. The APACHE II score, age and acute renal failure with concomitant need for dialysis were the factors best predicting mortality.
Conclusions: The majority of patients receiving prolonged mechanical ventilation can be successfully weaned using a standardized protocol. Failures of standardized weaning per protocol occurred most often in patients with chronic pulmonary disease and following longer inpatient stay. These patients also had a higher risk of final weaning failure.
Similar articles
-
Weaning injured patients with prolonged pulmonary failure from mechanical ventilation in a non-intensive care unit setting.J Trauma. 2000 Aug;49(2):224-30; discussion 230-1. doi: 10.1097/00005373-200008000-00007. J Trauma. 2000. PMID: 10963532
-
[Withdrawal from the respirator (weaning) in long-term ventilation. The results in patients in a weaning center].Dtsch Med Wochenschr. 1999 Sep 10;124(36):1022-8. doi: 10.1055/s-2007-1024476. Dtsch Med Wochenschr. 1999. PMID: 10506839 German.
-
Noninvasive ventilation during weaning from prolonged mechanical ventilation.Pulmonology. 2019 Nov-Dec;25(6):328-333. doi: 10.1016/j.pulmoe.2019.07.006. Epub 2019 Sep 10. Pulmonology. 2019. PMID: 31519534
-
[Experience of an intermediate respiratory intensive therapy in the treatment of prolonged weaning from mechanical ventilation].Minerva Anestesiol. 1996 Mar;62(3):57-64. Minerva Anestesiol. 1996. PMID: 8767150 Review. Italian.
-
Separation from mechanical ventilation and survival after spinal cord injury: a systematic review and meta-analysis.Ann Intensive Care. 2021 Oct 24;11(1):149. doi: 10.1186/s13613-021-00938-x. Ann Intensive Care. 2021. PMID: 34693485 Free PMC article. Review.
Cited by
-
[Weaning concepts in the setting of neurological disorders].Nervenarzt. 2017 Oct;88(10):1195-1196. doi: 10.1007/s00115-017-0419-7. Nervenarzt. 2017. PMID: 28929320 German. No abstract available.
-
Monitoring of Electrical Activity of the Diaphragm Shows Failure of T-Piece Trial Earlier than Protocol-Based Parameters in Prolonged Weaning in Non-communicative Neurological Patients.Neurocrit Care. 2017 Aug;27(1):35-43. doi: 10.1007/s12028-016-0360-9. Neurocrit Care. 2017. PMID: 28063121
-
[Weaning from dialysis after acute kidney injury in chronically critically ill].Med Klin Intensivmed Notfmed. 2019 Jun;114(5):459-462. doi: 10.1007/s00063-018-0488-9. Epub 2018 Oct 9. Med Klin Intensivmed Notfmed. 2019. PMID: 30302526 German.
-
[Augmented spontaneous breathing in the weaning process: technical gimmick or enrichment of intensive care medicine?].Anaesthesist. 2014 Apr;63(4):276-8. doi: 10.1007/s00101-014-2290-2. Anaesthesist. 2014. PMID: 24569932 German. No abstract available.
-