Estimation of maximal oxygen uptake via submaximal exercise testing in sports, clinical, and home settings
- PMID: 23821468
- DOI: 10.1007/s40279-013-0068-3
Estimation of maximal oxygen uptake via submaximal exercise testing in sports, clinical, and home settings
Abstract
Assessment of the functional capacity of the cardiovascular system is essential in sports medicine. For athletes, the maximal oxygen uptake [Formula: see text] provides valuable information about their aerobic power. In the clinical setting, the (VO(2max)) provides important diagnostic and prognostic information in several clinical populations, such as patients with coronary artery disease or heart failure. Likewise, VO(2max) assessment can be very important to evaluate fitness in asymptomatic adults. Although direct determination of [VO(2max) is the most accurate method, it requires a maximal level of exertion, which brings a higher risk of adverse events in individuals with an intermediate to high risk of cardiovascular problems. Estimation of VO(2max) during submaximal exercise testing can offer a precious alternative. Over the past decades, many protocols have been developed for this purpose. The present review gives an overview of these submaximal protocols and aims to facilitate appropriate test selection in sports, clinical, and home settings. Several factors must be considered when selecting a protocol: (i) The population being tested and its specific needs in terms of safety, supervision, and accuracy and repeatability of the VO(2max) estimation. (ii) The parameters upon which the prediction is based (e.g. heart rate, power output, rating of perceived exertion [RPE]), as well as the need for additional clinically relevant parameters (e.g. blood pressure, ECG). (iii) The appropriate test modality that should meet the above-mentioned requirements should also be in line with the functional mobility of the target population, and depends on the available equipment. In the sports setting, high repeatability is crucial to track training-induced seasonal changes. In the clinical setting, special attention must be paid to the test modality, because multiple physiological parameters often need to be measured during test execution. When estimating VO(2max), one has to be aware of the effects of medication on heart rate-based submaximal protocols. In the home setting, the submaximal protocols need to be accessible to users with a broad range of characteristics in terms of age, equipment, time available, and an absence of supervision. In this setting, the smart use of sensors such as accelerometers and heart rate monitors will result in protocol-free VO(2max) assessments. In conclusion, the need for a low-risk, low-cost, low-supervision, and objective evaluation of VO(2max) has brought about the development and the validation of a large number of submaximal exercise tests. It is of paramount importance to use these tests in the right context (sports, clinical, home), to consider the population in which they were developed, and to be aware of their limitations.
Similar articles
-
Prediction of maximal oxygen uptake from submaximal ratings of perceived exertion and heart rate during a continuous exercise test: the efficacy of RPE 13.Eur J Appl Physiol. 2009 Sep;107(1):1-9. doi: 10.1007/s00421-009-1093-7. Epub 2009 Jun 2. Eur J Appl Physiol. 2009. PMID: 19488778
-
Regulating intensity using perceived exertion during extended exercise periods.Eur J Appl Physiol. 2003 Jun;89(5):475-82. doi: 10.1007/s00421-003-0811-9. Epub 2003 Apr 24. Eur J Appl Physiol. 2003. PMID: 12712344 Clinical Trial.
-
A new VO₂max protocol allowing self-pacing in maximal incremental exercise.Br J Sports Med. 2012 Jan;46(1):59-63. doi: 10.1136/bjsports-2011-090006. Epub 2011 Apr 19. Br J Sports Med. 2012. PMID: 21505226
-
Methodological and practical application issues in exercise prescription using the heart rate reserve and oxygen uptake reserve methods.J Sci Med Sport. 2011 Jan;14(1):46-57. doi: 10.1016/j.jsams.2010.07.008. Epub 2010 Sep 15. J Sci Med Sport. 2011. PMID: 20833587 Review.
-
Prediction of maximal or peak oxygen uptake from ratings of perceived exertion.Sports Med. 2014 May;44(5):563-78. doi: 10.1007/s40279-013-0139-5. Sports Med. 2014. PMID: 24519666 Review.
Cited by
-
Application of a Web-Enabled Leg Training System for the Objective Monitoring and Quantitative Analysis of Exercise-Induced Fatigue.JMIR Res Protoc. 2016 Aug 22;5(3):e171. doi: 10.2196/resprot.4985. JMIR Res Protoc. 2016. PMID: 27549345 Free PMC article.
-
Enhancing performance: unveiling the physiological impact of submaximal and supramaximal tests on mixed martial arts athletes in the -61 kg and -66 kg weight divisions.Front Physiol. 2024 Jan 12;14:1257639. doi: 10.3389/fphys.2023.1257639. eCollection 2023. Front Physiol. 2024. PMID: 38283281 Free PMC article.
-
Cardiorespiratory Fitness as a Correlate of Cardiovascular, Anthropometric, and Physical Risk Factors: Using the Ruffier Test as a Template.Can Respir J. 2020 Sep 8;2020:3407345. doi: 10.1155/2020/3407345. eCollection 2020. Can Respir J. 2020. PMID: 32963643 Free PMC article.
-
Translation of lifestyle modification programs focused on physical activity and dietary habits delivered in community settings.Int J Behav Med. 2015 Jun;22(3):312-27. doi: 10.1007/s12529-014-9438-y. Int J Behav Med. 2015. PMID: 25200447 Review.
-
Proof of concept of a 45-second cardiorespiratory fitness self-test for coronary artery disease patients based on accelerometry.PLoS One. 2017 Sep 6;12(9):e0183740. doi: 10.1371/journal.pone.0183740. eCollection 2017. PLoS One. 2017. PMID: 28877186 Free PMC article. Clinical Trial.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous