In vivo dosimetry in brachytherapy
Abstract
In vivo dosimetry (IVD) has been used in brachytherapy (BT) for decades with a number of different detectors and measurement technologies. However, IVD in BT has been subject to certain difficulties and complexities, in particular due to challenges of the high-gradient BT dose distribution and the large range of dose and dose rate. Due to these challenges, the sensitivity and specificity toward error detection has been limited, and IVD has mainly been restricted to detection of gross errors. Given these factors, routine use of IVD is currently limited in many departments. Although the impact of potential errors may be detrimental since treatments are typically administered in large fractions and with high-gradient-dose-distributions, BT is usually delivered without independent verification of the treatment delivery. This Vision 20/20 paper encourages improvements within BT safety by developments of IVD into an effective method of independent treatment verification.
Similar articles
-
In vivo dosimetry in external beam radiotherapy.Med Phys. 2013 Jul;40(7):070903. doi: 10.1118/1.4811216. Med Phys. 2013. PMID: 23822404 Review.
-
Adaptive error detection for HDR/PDR brachytherapy: guidance for decision making during real-time in vivo point dosimetry.Med Phys. 2014 May;41(5):052102. doi: 10.1118/1.4870438. Med Phys. 2014. PMID: 24784391
-
In vivo dosimetry: trends and prospects for brachytherapy.Br J Radiol. 2014 Sep;87(1041):20140206. doi: 10.1259/bjr.20140206. Epub 2014 Jul 8. Br J Radiol. 2014. PMID: 25007037 Free PMC article. Review.
-
Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy.Med Phys. 2009 Nov;36(11):5033-43. doi: 10.1118/1.3238102. Med Phys. 2009. PMID: 19994514
-
Source position verification and dosimetry in HDR brachytherapy using an EPID.Med Phys. 2013 Nov;40(11):111706. doi: 10.1118/1.4823758. Med Phys. 2013. PMID: 24320414
Cited by
-
Optical fiber dosimeter for real-time in-vivo dose monitoring during LDR brachytherapy.Biomed Opt Express. 2020 Jun 30;11(7):4027-4036. doi: 10.1364/BOE.385610. eCollection 2020 Jul 1. Biomed Opt Express. 2020. PMID: 33014583 Free PMC article.
-
End-to-end test for computed tomography-based high-dose-rate brachytherapy.J Contemp Brachytherapy. 2018 Dec;10(6):551-558. doi: 10.5114/jcb.2018.81026. Epub 2018 Dec 28. J Contemp Brachytherapy. 2018. PMID: 30662478 Free PMC article.
-
In vivo dosimetry of the rectum in image-guided adaptive interstitial-intracavitary brachytherapy of cervix cancer - A feasibility study.Rep Pract Oncol Radiother. 2019 Mar-Apr;24(2):158-164. doi: 10.1016/j.rpor.2019.01.004. Epub 2019 Feb 14. Rep Pract Oncol Radiother. 2019. PMID: 30814915 Free PMC article.
-
High-dose rate intracavitary brachytherapy pretreatment dwell position verification using a transparent applicator.J Appl Clin Med Phys. 2018 Sep;19(5):428-434. doi: 10.1002/acm2.12405. Epub 2018 Jun 30. J Appl Clin Med Phys. 2018. PMID: 29959815 Free PMC article.
-
A swallowable X-ray dosimeter for the real-time monitoring of radiotherapy.Nat Biomed Eng. 2023 Oct;7(10):1242-1251. doi: 10.1038/s41551-023-01024-2. Epub 2023 Apr 13. Nat Biomed Eng. 2023. PMID: 37055542
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources