Feasibility of real-time three-dimensional echocardiography for the assessment of distorted biventricular systolic function in patients with cor pulmonale
- PMID: 23837116
- PMCID: PMC3701781
- DOI: 10.4250/jcu.2013.21.2.64
Feasibility of real-time three-dimensional echocardiography for the assessment of distorted biventricular systolic function in patients with cor pulmonale
Abstract
Background: This study was to investigate the feasibility of real-time 3-dimensional echocardiography (RT3DE) for the analysis of biventricular ejection fractions and volume measurements in patients with cor pulmonale and the correlations of RT3DE results with 64-slice multi-detector cardiac computed tomography (64-MDCT) results.
Methods: This study included a total of 22 patients (59.3 ± 16.6 years of age; 10 males and 12 females) who showed flattening or reverse curvature of the interventricular septum and severe pulmonary hypertension [mean right ventricular (RV) systolic pressure = 66.8 ± 19.7 mmHg] on 2-dimensional transthoracic echocardiography due to cor pulmonale. Biventricular end-diastolic and end-systolic volumes were measured by RT3DE and 64-MDCT. The severity of D-shaped deformation was evaluated by using left ventricular (LV) eccentricity index (ratio of diameters parallel/perpendicular to the interventricular septum on parasternal short axis images of the papillary muscle level).
Results: There were moderate correlations between biventricular volumes measured by RT3DE and 64-MDCT except for LV end-systolic volume (59.8 ± 17.1 vs. 73.2 ± 20.2 mL, r = 0.652, p = 0.001 for LV end-diastolic volume; 30.6 ± 9.1 vs. 30.8 ± 12.5 mL, r = 0.361, p = 0.099 for LV end-systolic volume; 110.1 ± 42.9 vs. 171.1 ± 55.3 mL, r = 0.545, p = 0.009 for RV end-diastolic volume; and 80.9 ± 35.0 vs. 128.7 ± 45.1 mL, r = 0.549, p = 0.005 for RV end-systolic volume respectively).
Conclusion: This study suggests that RT3DE may be a modest method for measuring distorted biventricular end-systolic and end-diastolic volumes in patients with cor pulmonale.
Keywords: 64-slice multi-detector cardiac computed tomography; Cor pulmonale; D-shaped deformation; Real-time three-dimensional echocardiography; Severe pulmonary hypertension.
Figures



References
-
- Grapsa J, O'Regan DP, Pavlopoulos H, Durighel G, Dawson D, Nihoyannopoulos P. Right ventricular remodelling in pulmonary arterial hypertension with three-dimensional echocardiography: comparison with cardiac magnetic resonance imaging. Eur J Echocardiogr. 2010;11:64–73. - PubMed
-
- Torbicki A, Skwarski K, Hawrylkiewicz I, Pasierski T, Miskiewicz Z, Zielinski J. Attempts at measuring pulmonary arterial pressure by means of Doppler echocardiography in patients with chronic lung disease. Eur Respir J. 1989;2:856–860. - PubMed
-
- Barberà JA, Peinado VI, Santos S. Pulmonary hypertension in chronic obstructive pulmonary disease. Eur Respir J. 2003;21:892–905. - PubMed
-
- Laaban JP, Diebold B, Zelinski R, Lafay M, Raffoul H, Rochemaure J. Noninvasive estimation of systolic pulmonary artery pressure using Doppler echocardiography in patients with chronic obstructive pulmonary disease. Chest. 1989;96:1258–1262. - PubMed
-
- Naeije R, Torbicki A. More on the noninvasive diagnosis of pulmonary hypertension: Doppler echocardiography revisited. Eur Respir J. 1995;8:1445–1449. - PubMed
LinkOut - more resources
Full Text Sources
Other Literature Sources