Reducing radiation dose in CT enterography
- PMID: 23842974
- DOI: 10.1148/rg.334125074
Reducing radiation dose in CT enterography
Abstract
Computed tomographic (CT) enterography is a diagnostic examination that is increasingly being used to evaluate disorders of the small bowel. An undesirable consequence of CT, however, is patient exposure to ionizing radiation. This is of particular concern with CT enterography because patients tend to be young and require numerous follow-up examinations. There are multiple strategies to reduce radiation dose at CT enterography, including adjusting acquisition parameters, reducing scan length, and reducing tube voltage or tube current. The drawback to dose reduction strategies is degradation of image quality due to increased image noise. However, image noise can be reduced with commercial iterative reconstruction and denoising techniques. With a combination of low-dose techniques and noise-control strategies, one can markedly reduce radiation dose at CT enterography while maintaining diagnostic accuracy.
Similar articles
-
CT enterography at 100 kVp with iterative reconstruction compared to 120 kVp filtered back projection: evaluation of image quality and radiation dose in the same patients.Abdom Imaging. 2014 Dec;39(6):1255-60. doi: 10.1007/s00261-014-0156-3. Abdom Imaging. 2014. PMID: 24802547
-
Feasibility of dose reduction using novel denoising techniques for low kV (80 kV) CT enterography: optimization and validation.Acad Radiol. 2010 Oct;17(10):1203-10. doi: 10.1016/j.acra.2010.07.001. Acad Radiol. 2010. PMID: 20832023 Free PMC article.
-
CT enterography: technical and interpretive pitfalls.Abdom Imaging. 2015 Jun;40(5):1081-96. doi: 10.1007/s00261-015-0364-5. Abdom Imaging. 2015. PMID: 25652953 Review.
-
Dose reduction in cardiothoracic CT: review of currently available methods.Radiographics. 2014 Oct;34(6):1469-89. doi: 10.1148/rg.346140084. Radiographics. 2014. PMID: 25310412 Review.
-
A prospective comparison of standard-dose CT enterography and 50% reduced-dose CT enterography with and without noise reduction for evaluating Crohn disease.AJR Am J Roentgenol. 2011 Jul;197(1):50-7. doi: 10.2214/AJR.11.6582. AJR Am J Roentgenol. 2011. PMID: 21701010
Cited by
-
Dual-source abdominopelvic computed tomography: Comparison of image quality and radiation dose of 80 kVp and 80/150 kVp with tin filter.PLoS One. 2020 Sep 3;15(9):e0231431. doi: 10.1371/journal.pone.0231431. eCollection 2020. PLoS One. 2020. PMID: 32881876 Free PMC article.
-
Feasibility of thin-slice abdominal CT in overweight patients using a vendor neutral image-based denoising algorithm: Assessment of image noise, contrast, and quality.PLoS One. 2019 Dec 17;14(12):e0226521. doi: 10.1371/journal.pone.0226521. eCollection 2019. PLoS One. 2019. PMID: 31846490 Free PMC article.
-
Intestinal tuberculosis versus crohn's disease: Clinical and radiological recommendations.Indian J Radiol Imaging. 2016 Apr-Jun;26(2):161-72. doi: 10.4103/0971-3026.184417. Indian J Radiol Imaging. 2016. PMID: 27413261 Free PMC article.
-
The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography: Effects on image quality and radiation dose.Medicine (Baltimore). 2018 Mar;97(12):e0151. doi: 10.1097/MD.0000000000010151. Medicine (Baltimore). 2018. PMID: 29561422 Free PMC article.
-
Diagnostic performance and image quality of an image-based denoising algorithm applied to radiation dose-reduced CT in diagnosing acute appendicitis.Abdom Radiol (NY). 2024 Jun;49(6):1839-1849. doi: 10.1007/s00261-024-04246-3. Epub 2024 Feb 27. Abdom Radiol (NY). 2024. PMID: 38411690 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical