Fracture of ceramic bearing surfaces following total hip replacement: a systematic review
- PMID: 23844356
- PMCID: PMC3697280
- DOI: 10.1155/2013/157247
Fracture of ceramic bearing surfaces following total hip replacement: a systematic review
Abstract
Ceramic bearing surfaces are increasingly used for total hip replacement, notwithstanding that concern is still related to ceramic brittleness and its possible mechanical failure. The aim of this systematic review is to answer three questions: (1) Are there risk factors for ceramic component fracture following total hip replacement? (2) Is it possible to perform an early diagnosis of ceramic component failure before catastrophic fracture occurs? (3) Is it possible to draw guidelines for revision surgery after ceramic components failure? A PubMed and Google Scholar search was performed and reference citations from publications identified in the literature search were reviewed. The use of 28 mm short-neck femoral head carries an increased risk of fracture. Acetabular component malposition might increase the risk of ceramic liner fractures. Synovial fluid microanalysis and CT scan are promising in early diagnosis of ceramic head and liner failure. Early revision is suggested in case of component failure; no consensus exists about the better coupling for revision surgery. Ceramic brittleness remains a major concern. Due to the increased number of ceramic on ceramic implants, more revision surgeries and reports on ceramic components failure are expected in the future. An algorithm of diagnosis and treatment for ceramic hip failure is proposed.
Figures



Similar articles
-
There Are No Differences in Short- to Mid-term Survivorship Among Total Hip-bearing Surface Options: A Network Meta-analysis.Clin Orthop Relat Res. 2015 Jun;473(6):2031-41. doi: 10.1007/s11999-014-4065-0. Epub 2014 Dec 17. Clin Orthop Relat Res. 2015. PMID: 25516002 Free PMC article.
-
Total hip replacement and surface replacement for the treatment of pain and disability resulting from end-stage arthritis of the hip (review of technology appraisal guidance 2 and 44): systematic review and economic evaluation.Health Technol Assess. 2015 Jan;19(10):1-668, vii-viii. doi: 10.3310/hta19100. Health Technol Assess. 2015. PMID: 25634033 Free PMC article.
-
What Are the Functional, Radiographic, and Survivorship Outcomes of a Modified Cup-cage Technique for Pelvic Discontinuity?Clin Orthop Relat Res. 2024 Dec 1;482(12):2149-2160. doi: 10.1097/CORR.0000000000003186. Epub 2024 Jul 9. Clin Orthop Relat Res. 2024. PMID: 38991223
-
Is a ceramic-on-ceramic bearing really superior to ceramic-on-polyethylene for primary total hip arthroplasty? A systematic review and meta-analysis of randomised controlled trials.Hip Int. 2015 May-Jun;25(3):191-8. doi: 10.5301/hipint.5000223. Epub 2015 Feb 12. Hip Int. 2015. PMID: 25684252
-
Are There Differences in Performance Among Femoral Stem Brands Utilized in Cementless Hemiarthroplasty for Treatment of Geriatric Femoral Neck Fractures?Clin Orthop Relat Res. 2025 Feb 1;483(2):253-264. doi: 10.1097/CORR.0000000000003222. Epub 2024 Aug 15. Clin Orthop Relat Res. 2025. PMID: 39158389
Cited by
-
Outcome after Two Sequential Revision Hip Arthroplasties for CoC Bearing Fracture with 10 Years Follow-up: A Case Report.J Orthop Case Rep. 2021 Jul;11(7):45-48. doi: 10.13107/jocr.2021.v11.i07.2310. J Orthop Case Rep. 2021. PMID: 34790602 Free PMC article.
-
Adverse local tissue reaction after 2 revision hip replacements for ceramic liner fracture: A case report.Medicine (Baltimore). 2017 May;96(19):e6687. doi: 10.1097/MD.0000000000006687. Medicine (Baltimore). 2017. PMID: 28489745 Free PMC article.
-
Management and Outcomes of Breakage in Polyethylene-Ceramic Composite (Sandwich-type) Liners: Lessons From Long-term Follow-up.Arthroplast Today. 2025 May 9;33:101698. doi: 10.1016/j.artd.2025.101698. eCollection 2025 Jun. Arthroplast Today. 2025. PMID: 40475005 Free PMC article.
-
Imaging of ceramic liner fractures in total hip arthroplasty: the value of CT.Skeletal Radiol. 2015 Aug;44(8):1189-92. doi: 10.1007/s00256-015-2122-8. Epub 2015 Mar 7. Skeletal Radiol. 2015. PMID: 25744811
-
Effect of Femoral Head Material, Surgeon Experience, and Assembly Technique on Simulated Head-Neck Total Hip Arthroplasty Impaction Forces.J Arthroplasty. 2024 Feb;39(2):507-513.e1. doi: 10.1016/j.arth.2023.08.049. Epub 2023 Aug 19. J Arthroplasty. 2024. PMID: 37598779 Free PMC article.
References
-
- Bos I, Willmann G. Morphologic characteristics of periprosthetic tissues from hip prostheses with ceramic-ceramic couples: a comparative histologic investigation of 18 revision and 30 autopsy cases. Acta Orthopaedica Scandinavica. 2001;72(4):335–342. - PubMed
-
- Christel PS. Biocompatibility of surgical-grade dense polycrystalline alumina. Clinical Orthopaedics and Related Research. 1992;(282):10–18. - PubMed
-
- Gudena R, Kuna S, Pradhan N. Aseptic loosening of total hip replacement presenting as an anterior thigh mass. Musculoskeletal Surgery. 2011 - PubMed
-
- Spinarelli A, Patella V, Petrera M, Abate A, Pesce V, Patella S. Heterotopic ossification after total hip arthroplasty: our experience. Musculoskeletal surgery. 2011;95(1):1–5. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical