. 1990 Jun;5(2):57-64.
doi: 10.1007/BF01001046.

Ultra-high performance, solid-state, autoradiographic image digitization and analysis system

Affiliations

Ultra-high performance, solid-state, autoradiographic image digitization and analysis system

J L Lear et al. Metab Brain Dis. 1990 Jun.

Abstract

We developed a Macintosh II-based, charge-coupled device (CCD), image digitization and analysis system for high-speed, high-resolution quantification of autoradiographic image data. A linear CCD array with 3,500 elements was attached to a precision drive assembly and mounted behind a high-uniformity lens. The drive assembly was used to sweep the array perpendicularly to its axis so that an entire 20 x 25-cm autoradiographic image-containing film could be digitized into 256 gray levels at 50-microns resolution in less than 30 sec. The scanner was interfaced to a Macintosh II computer through a specially constructed NuBus circuit board and software was developed for autoradiographic data analysis. The system was evaluated by scanning individual films multiple times, then measuring the variability of the digital data between the different scans. Image data were found to be virtually noise free. The coefficient of variation averaged less than 1%, a value significantly exceeding the accuracy of both high-speed, low-resolution, video camera (VC) systems and low-speed, high-resolution, rotating drum densitometers (RDD). Thus, the CCD scanner-Macintosh computer analysis system offers the advantage over VC systems of the ability to digitize entire films containing many autoradiograms, but with much greater speed and accuracy than achievable with RDD scanners.

PubMed Disclaimer

References

    1. J Neurosci Methods. 1984 Mar;10(3):173-88 - PubMed
    1. J Cereb Blood Flow Metab. 1985 Sep;5(3):481-2 - PubMed
    1. J Nucl Med. 1983 Mar;24(3):238-44 - PubMed
    1. J Nucl Med. 1986 Apr;27(4):549-54 - PubMed
    1. Ann Neurol. 1980 Apr;7(4):359-70 - PubMed

Publication types