Influence of diabetes mellitus on inappropriate and appropriate implantable cardioverter-defibrillator therapy and mortality in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) Trial
- PMID: 23881862
- DOI: 10.1161/CIRCULATIONAHA.113.002472
Influence of diabetes mellitus on inappropriate and appropriate implantable cardioverter-defibrillator therapy and mortality in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) Trial
Abstract
Background: The relationship between diabetes mellitus and risk of inappropriate or appropriate therapy in patients receiving an implantable cardioverter-defibrillator (ICD) and resynchronization therapy has not been investigated thoroughly. The effect of innovative ICD programming on therapy delivery in these patients is unknown.
Methods and results: The Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) randomized patients with a primary prophylactic ICD indication to 3 different types of ICD programming: conventional programming with a ventricular tachycardia zone of 170 to 199 bpm (arm A), high-rate cutoff with a ventricular tachycardia zone ≥200 bpm (arm B), or 60-second-delayed therapy (arm C). The end points of inappropriate therapy, appropriate therapy, and death were assessed among 485 patients with and 998 without diabetes mellitus. Innovative ICD programming reduced the risk of inappropriate therapy regardless of diabetes mellitus, although a trend toward a more pronounced effect of high-rate cutoff programming was seen in patients without diabetes mellitus (P for interaction=0.06). Diabetes mellitus was associated with a decreased risk of inappropriate therapy (hazard ratio, 0.54; 95% confidence interval, 0.36-0.80; P=0.002) and increased risk of appropriate therapy (hazard ratio, 1.58; 95% confidence interval, 1.17-2.14; P=0.003). In diabetic patients, there was significantly increased risk of death in those who had inappropriate therapy (hazard ratio, 4.17; 95% confidence interval, 1.52-11.40; P=0.005) and appropriate therapy (hazard ratio, 2.49; 95% confidence interval, 1.06-5.87; P=0.037) compared with those who did not.
Conclusions: Innovative high-rate cutoff or delayed ICD programming was associated with a reduction in inappropriate therapy in patients with and without diabetes mellitus. Diabetes mellitus was associated with lower risk of inappropriate therapy but higher risk of appropriate therapy. Appropriate and inappropriate ICD therapy was associated with increased mortality in diabetic patients.
Clinical trial registration: URL: http://www.clinicaltrials.gov. UNIQUE IDENTIFIER: NCT00947310.
Keywords: defibrillators, implantable; diabetes mellitus; heart failure; mortality.
Similar articles
-
Mortality reduction in relation to implantable cardioverter defibrillator programming in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT).Circ Arrhythm Electrophysiol. 2014 Oct;7(5):785-92. doi: 10.1161/CIRCEP.114.001623. Epub 2014 Aug 18. Circ Arrhythm Electrophysiol. 2014. PMID: 25136077 Clinical Trial.
-
Novel ICD Programming and Inappropriate ICD Therapy in CRT-D Versus ICD Patients: A MADIT-RIT Sub-Study.Circ Arrhythm Electrophysiol. 2016 Jan;9(1):e001965. doi: 10.1161/CIRCEP.114.001965. Circ Arrhythm Electrophysiol. 2016. PMID: 26743237 Clinical Trial.
-
Syncope in high-risk cardiomyopathy patients with implantable defibrillators: frequency, risk factors, mechanisms, and association with mortality: results from the multicenter automatic defibrillator implantation trial-reduce inappropriate therapy (MADIT-RIT) study.Circulation. 2014 Feb 4;129(5):545-52. doi: 10.1161/CIRCULATIONAHA.113.004196. Epub 2013 Nov 7. Circulation. 2014. PMID: 24201303 Clinical Trial.
-
Implantable cardioverter defibrillators in arrhythmogenic right ventricular dysplasia/cardiomyopathy: patient outcomes, incidence of appropriate and inappropriate interventions, and complications.Circ Arrhythm Electrophysiol. 2013 Jun;6(3):562-8. doi: 10.1161/CIRCEP.113.000392. Epub 2013 May 14. Circ Arrhythm Electrophysiol. 2013. PMID: 23673907 Review.
-
Programming implantable cardioverter-defibrillators in primary prevention: higher or later.Arch Cardiovasc Dis. 2014 May;107(5):308-18. doi: 10.1016/j.acvd.2014.03.006. Epub 2014 May 16. Arch Cardiovasc Dis. 2014. PMID: 24834904 Review.
Cited by
-
[Sudden cardiac death in diabetes mellitus].Herz. 2016 May;41(3):193-200. doi: 10.1007/s00059-016-4421-9. Herz. 2016. PMID: 27071967 Review. German.
-
Influence of diabetes on mortality and ICD therapies in ICD recipients: a systematic review and meta-analysis of 162,780 patients.Cardiovasc Diabetol. 2022 Jul 29;21(1):143. doi: 10.1186/s12933-022-01580-y. Cardiovasc Diabetol. 2022. PMID: 35906611 Free PMC article.
-
Right atrium area is associated with survival after out-of-hospital cardiac arrest: a single-center cohort study.Echo Res Pract. 2025 Apr 14;12(1):9. doi: 10.1186/s44156-025-00072-5. Echo Res Pract. 2025. PMID: 40223106 Free PMC article.
-
Predictors of mortality and ICD shock therapy in primary prophylactic ICD patients-A systematic review and meta-analysis.PLoS One. 2017 Oct 17;12(10):e0186387. doi: 10.1371/journal.pone.0186387. eCollection 2017. PLoS One. 2017. PMID: 29040341 Free PMC article.
-
Risk prediction of inappropriate implantable cardioverter-defibrillator therapy using machine learning.Sci Rep. 2023 Nov 9;13(1):19586. doi: 10.1038/s41598-023-46095-y. Sci Rep. 2023. PMID: 37949876 Free PMC article.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical