. 2014 Jan;46(1):169-74.
doi: 10.1007/s11255-013-0500-5. Epub 2013 Jul 25.

Lung ultrasound during hemodialysis: the role in the assessment of volume status

Affiliations

Lung ultrasound during hemodialysis: the role in the assessment of volume status

Nicola Vitturi et al. Int Urol Nephrol. 2014 Jan.

Abstract

Objective: Fluid balance is important in patients undergoing hemodialysis. "Dry" weight is usually estimated clinically, and also, bioimpedance is considered reliable. Ultrasonography of inferior vena cava (IVC) estimates central venous pressure, and lung ultrasound evaluates extravascular (counting B-lines artifact) lung water. Our study was aimed to clarify their usefulness in the assessment of volume status during hemodialysis.

Methods: A total of 71 consecutive patients undergoing hemodialysis underwent lung and IVC ultrasound and bioimpedance spectroscopy immediately before and after dialysis.

Results: There was a significant reduction in the number of B-lines (3.13 vs 1.41) and in IVC diameters (end-expiratory diameter 1.71 vs 1.37; end-inspiratory diameter 1.19 vs 0.95) during dialysis. The reduction in B-lines correlated with weight reduction during dialysis (p 0.007); none of the parameters concerning the IVC correlated with fluid removal. At the end of the dialysis session, the total number of B-lines correlated with bioimpedance residual weight (p 0.002).

Discussion: The reduction in B-lines correlated with fluid loss due to hemodialysis, despite the small pre-dialysis number, confirming that lung ultrasound can identify even modest variations in extravascular lung water. IVC ultrasound, which reflects the intravascular filling grade, might not be sensitive enough to detect rapid volume decrease. Clinically estimated dry weight had a poor correlation with both bioimpedance and ultrasound techniques. Post-dialysis B-lines number correlates with residual weight assessed with bioimpedance, suggesting a role for ultrasound in managing hemodialysis patients.

PubMed Disclaimer

References

    1. J Am Soc Nephrol. 1999 Feb;10(2):392-403 - PubMed
    1. Nephrol Dial Transplant. 1989;4(6):563-8 - PubMed
    1. Intensive Care Med. 2004 Sep;30(9):1834-7 - PubMed
    1. J Cardiovasc Pharmacol. 1982;4 Suppl 2:S257-61 - PubMed
    1. Nephrol Dial Transplant. 1996;11 Suppl 2:20-3 - PubMed

LinkOut - more resources