Acceleration-based joint stability parameters for total knee arthroplasty that correspond with patient-reported instability
- PMID: 23886970
- DOI: 10.1177/0954411913493724
Acceleration-based joint stability parameters for total knee arthroplasty that correspond with patient-reported instability
Abstract
There is no universally accepted definition of human joint stability, particularly in nonperiodic general activities of daily living. Instability has proven to be a difficult parameter to define and quantify, since both spatial and temporal measures need to be considered to fully characterize joint stability. In this preliminary study, acceleration-based parameters were proposed to characterize the joint stability. Several time-statistical parameters of acceleration and jerk were defined as potential stability measures, since anomalous acceleration or jerk could be a symptom of poor control or stability. An inertial measurement unit attached at the level of the tibial tubercle of controls and patients following total knee arthroplasty was used to determine linear acceleration of the knee joint during several activities of daily living. The resulting accelerations and jerks were compared with patient-reported instability as determined through a standard questionnaire. Several parameters based on accelerations and jerks in the anterior/posterior direction during the step-up/step-down activity were significantly different between patients and controls and correlated with patient reports of instability in that activity. The range of the positive to negative peak acceleration and infinity norm of acceleration, in the anterior/posterior direction during the step-up/step-down activity, proved to be the best indicators of instability. As time derivatives of displacement, these acceleration-based parameters represent spatial and temporal information and are an important step forward in developing a definition and objective quantification of human joint stability that can complement the subjective patient report.
Keywords: Acceleration; activities of daily living; inertial measurement unit; jerk; joint stability; patient report; stability; total knee arthroplasty; total knee replacement.
Similar articles
-
The potential of accelerometers in the evaluation of stability of total knee arthroplasty.J Arthroplasty. 2013 Mar;28(3):459-62. doi: 10.1016/j.arth.2012.07.025. Epub 2012 Nov 2. J Arthroplasty. 2013. PMID: 23122873
-
No differences in objective dynamic instability during acceleration of the knee with or without subjective instability post-total knee arthroplasty.PLoS One. 2018 Mar 16;13(3):e0194221. doi: 10.1371/journal.pone.0194221. eCollection 2018. PLoS One. 2018. PMID: 29547641 Free PMC article.
-
Malrotation in total knee arthroplasty: effect on tibial cortex strain captured by laser-based strain acquisition.Clin Biomech (Bristol). 2006 Jul;21(6):603-9. doi: 10.1016/j.clinbiomech.2006.01.011. Epub 2006 Mar 22. Clin Biomech (Bristol). 2006. PMID: 16554112
-
Tibiofemoral instability in primary total knee replacement: A review Part 2: diagnosis, patient evaluation, and treatment.Knee. 2005 Oct;12(5):336-40. doi: 10.1016/j.knee.2005.01.005. Knee. 2005. PMID: 16137888 Review. No abstract available.
-
Instability after total knee arthroplasty.Instr Course Lect. 2008;57:295-304. Instr Course Lect. 2008. PMID: 18399593 Review.
Cited by
-
Motion Sensors-Based Machine Learning Approach for the Identification of Anterior Cruciate Ligament Gait Patterns in On-the-Field Activities in Rugby Players.Sensors (Basel). 2020 May 27;20(11):3029. doi: 10.3390/s20113029. Sensors (Basel). 2020. PMID: 32471051 Free PMC article.
-
Wearable sensor systems measure differences in knee laxity between healthy and affected knees during dynamic exercise activities: A systematic review.J Exp Orthop. 2024 Jul 24;11(3):e12094. doi: 10.1002/jeo2.12094. eCollection 2024 Jul. J Exp Orthop. 2024. PMID: 39055395 Free PMC article. Review.
-
A machine learning approach using gait parameters to cluster TKA subjects into stable and unstable joints for discovery analysis.Knee. 2025 Jun;54:167-177. doi: 10.1016/j.knee.2025.02.018. Epub 2025 Mar 11. Knee. 2025. PMID: 40073701
-
Current clinical utilisation of wearable motion sensors for the assessment of outcome following knee arthroplasty: a scoping review.BMJ Open. 2019 Dec 29;9(12):e033832. doi: 10.1136/bmjopen-2019-033832. BMJ Open. 2019. PMID: 31888943 Free PMC article.
-
A Systematic Review of Diagnostic Accuracy and Clinical Applications of Wearable Movement Sensors for Knee Joint Rehabilitation.Sensors (Basel). 2021 Dec 9;21(24):8221. doi: 10.3390/s21248221. Sensors (Basel). 2021. PMID: 34960315 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials