Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2013 Aug;154(2):328-34.
doi: 10.1016/j.surg.2013.04.036.

An institutional analysis and systematic review with meta-analysis of pneumatic versus hydrostatic reduction for pediatric intussusception

Affiliations
Meta-Analysis

An institutional analysis and systematic review with meta-analysis of pneumatic versus hydrostatic reduction for pediatric intussusception

Alana L Beres et al. Surgery. 2013 Aug.

Abstract

Background: Intussusception remains a frequent cause of bowel obstruction in children and typically is treated by reduction via enema. Controversy persists regarding the optimal reduction technique to maximize success while minimizing morbidity.

Methods: We reviewed our institutional data comparing outcomes of enema reduction that use contrast medium versus air. A systematic review also was undertaken of comparative studies evaluating pneumatic (oxygen or air) versus hydrostatic (any contrast medium) reduction. Critical appraisal was performed with the Methodological Index for Non Randomized Studies scale for observational studies, Jadad score for randomized trials. Meta-analysis was performed with REVMAN 5.1.

Results: Institutional data revealed a failed reduction rate of 20.4% (20/98) with air and 29.6% (8/27) with contrast reduction. Nineteen studies were included in the systematic review. The cumulative failure rate favored pneumatic reduction (odds ratio [OR] 0.45; 95% confidence interval [95% CI] 0.34-0.60); sensitivity analysis of prospective studies demonstrated similar results (OR 0.39; 95% CI 0.24-0.63). The number needed to treat to eliminate one failed reduction was nine pneumatic reductions. No difference was noted in reported perforations (OR 0.98; 95% CI 0.48-2.03).

Conclusion: Pneumatic reduction is more likely to successfully reduce intussusception in children without evidence of increased morbidity. In the context of available expertise, pneumatic reduction should be the method of choice for the treatment of intussusception barring an indication for immediate operative intervention.

PubMed Disclaimer