Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Oct;118(7):1212-9.
doi: 10.1007/s11547-013-0967-2. Epub 2013 Jul 25.

Fiducial markers for image-guided partial breast irradiation

Affiliations

Fiducial markers for image-guided partial breast irradiation

Marco Trovo et al. Radiol Med. 2013 Oct.

Abstract

Purpose: This study was undertaken to study the role of fiducial markers for image-guided partial breast irradiation (IG-PBI), and to compare the shifts based on bony anatomy and fiducial markers.

Materials and methods: Fifteen patients underwent IGPBI. Three fiducial markers were placed in the tumour bed at the time of surgery. Daily orthogonal anterior/ posterior and lateral kV-images were taken before each fraction and compared with the digitally-reconstructed radiographs, both using bony landmarks and fiducial markers as reference. The Student's t test was used to detect a meaningful difference of 3 mm in between the two methods.

Results: A total of 105 image-guided radiation therapy (IGRT) sessions were obtained. The mean superior/inferior, right/left, and anterior/posterior shifts obtained using the bony landmarks vs. the fiducial markers were 2 mm [standard deviation (SD) 10 mm] vs. 0 mm (SD 7 mm), 0 mm (SD 7 mm) vs. 1 mm (SD 4 mm), and 1 mm (SD 7 mm) vs. 0 mm (SD 5 mm), respectively. The mean shift differences in absolute value between the two methods, along the superior/inferior, right/left and anterior/posterior directions were 5 mm (p=0.001), 3 mm [p=not significant (ns)], and 3 mm (p=ns), respectively.

Conclusions: Fiducial markers for IG-PBI increase set-up accuracy compared to the bony landmarks, in particular along the superior/inferior direction.

PubMed Disclaimer

References

    1. Int J Radiat Oncol Biol Phys. 2010 Feb 1;76(2):528-34 - PubMed
    1. N Engl J Med. 2002 Oct 17;347(16):1233-41 - PubMed
    1. Int J Radiat Oncol Biol Phys. 2003 Dec 1;57(5):1247-53 - PubMed
    1. Lancet Oncol. 2006 Oct;7(10):848-58 - PubMed
    1. Int J Radiat Oncol Biol Phys. 2007 Jun 1;68(2):547-54 - PubMed

LinkOut - more resources