Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Nov;48(11):779-86.
doi: 10.1097/RLI.0b013e31829705bb.

Quantitative evaluation of computed high B value diffusion-weighted magnetic resonance imaging of the prostate

Affiliations

Quantitative evaluation of computed high B value diffusion-weighted magnetic resonance imaging of the prostate

Marnix C Maas et al. Invest Radiol. 2013 Nov.

Abstract

Objectives: Computed diffusion-weighted magnetic resonance imaging (cDWI) refers to the synthesizing of arbitrary b value diffusion-weighted images (DWI) from a set of measured b value images by voxelwise fitting. The objectives of this study were to quantitatively analyze the noise and the contrast-to-noise ratio (CNR) in cDWI as a function of b value by numerical simulations and by measurements in patients with prostate cancer and to compare cDWI to directly measured DWI at a b value of 1400 s/mm2.

Materials and methods: Numerical simulations were performed to assess image noise and CNR in both cDWI and regular DWI. Forty-two patients with prostate cancer (age, 51-73 years; prostate specific antigen level, 0.5-30 ng/mL; and biopsy Gleason score, 6-9) received 2 DWI examinations at 3.0 T (one with b values of 100, 500, and 1400 s/mm2 and another with b values of 0, 100, 400, and 800 s/mm2) to create cDWI images at arbitrary b values, both with and without incorporating a b value of 0 s/mm2 in their calculation. Regions of interest were drawn to compare the scan time adjusted CNR (CNR eff) between cDWI and directly measured DWI at b = 1400 s/mm2 on tumor-suspicious lesions and normal-appearing regions.

Results: In the numerical simulations, noise depended strongly on the b value, the diffusion coefficient, and the signal intensity at a b value of 0 s/mm2 in cDWI but not in regular DWI. The CNR between simulated tumor and normal regions showed a continuous increase with increasing b value. Both these findings were also observed in tumor-suspicious and normal-appearing regions in in vivo data. In vivo prostate DWI at a b value of 1400 s/mm2 showed a similar CNR eff between the tumor-suspicious regions and the normal-appearing tissue in cDWI as in the directly measured DWI (P = 0.395).

Conclusions: The CNR eff between tumor-suspicious and normal-appearing prostate tissue in DWI images at a b value of 1400 s/mm2 is comparable in cDWI and directly measured DWI. Computed DWI at even higher b values, calculated from measured images with b values between 0 and 800 s/mm2, yields higher CNR eff than measured DWI, which may be of clinical aid in the management of prostate cancer.

PubMed Disclaimer

Publication types

Substances